Figure 8: mlr1 timer controls (shown uninstalled) – Aalborg TPV User Manual
Page 23
23
5.4 Programming the TPURP MLR1 Timer (if present)
The TPURP timer relay can be set to dispense liquid over a
chosen time period, and to stop dispensing for another chosen
time period. With reference to Figure 8, use the top set of
knobs on the MLR1 timer relay for setting up the dispensing
ON mode, and use the bottom set for setting up the non-
dispensing OFF mode.
FIGURE 8: MLR1 TIMER CONTROLS
(shown uninstalled)
1 ON Time Period knob
3 OFF Time period knob
2 ON Multiplication knob
4 OFF Multiplication knob
The pump can be set to dispense ON and OFF for any of the
following 7 time periods:
1. 0.1 – 1 sec
5. 6 – 60 min
2. 1 – 10 sec
6. 1 – 10 hr
3. 6 – 60 sec
7. 10 – 100 hr
4. 1 – 10 min
1
2
3
4
This manual is related to the following products: