5. OPERATING INSTRUCTIONS
5.1 Powering On
1. After you verify that your power cord plug is suitable for
your electrical supply, connect the cord to the back of the
pump case, then plug it into your power outlet.
2. On the back of the pump, turn the on/off power switch ON.
3. If your pump has a Run/Brake switch, turning the switch to
Run will turn the pump on.
5.2 Priming the Pump
With one end of the tubing in the liquid you need to pump, and
the other end in the target receptable or appropriately
clamped to the target site:
If your pump has a Prime button, press and hold the button
at Maximum Speed for a few seconds, until the liquid is
successfully suctioned into the tubing.
If your pump does not have a Prime button, turn the pump
On (main power switch on back). The amount of time it will
take for the pump to prime depends on the preset pump
speed.