Aalborg PWE Digital User Manual
Page 74

69
COMMAND
NAME
DESCRIPTION
NO.
COMMAND SYNT
A
X
COMMAND
ARGUMENT 1
ARGUMENT 2
ARGUMENT 3
ARGUMENT 4
RESPONSE
Maintenance
Ti
m
er
Hours since last time unit was
calibrated.
NOTE: has to be reset to zero
after calibration.
14
C
R (read timer)
CR:
Z (set timer to
zero)
CZ
Pulse
Measure
Inter
val
Display/Change Meter Pulse
Measure Inter
val settings
Note: Pulse Measure Inter
val
has to be in the range:
500mS
MI
60000 mS
15
I
mS
I:
Example: I:2000
No Argument
(Returns Current
MI settings in mS)
I:
Example: I:2000
Flow
Measure
Mode
Display/Change Meter Flow
Measuring Mode
Following measurement
modes are supported:
W -
P
ulse Width
C -
Number of Pulses per
measure inter
val
16
MM
W - Pulse Width*
C - # of Pulses
MM:
Example: MM:W
No Argument
(Returns Current
settings)
MM:
Example: MM:W
Flow Meter
Linearizer
Enable/Disable flow meter
Linearizer
17
FL
alue> E or D FL: Example: FL:E No Argument (Returns Current Linearizer settings) FL: Example: FL:E LCD Back Light** Display/Change LCD Back Light settings Note: LCD Back Light settings has to be in the range: 0 % B L 8 0 % 18 BL (New LCD Back Light value) 0 - 80% BL: alue> Example: BL:50 No Argument (Returns Current LCD Back Light settings) BL: < BL V alue > Example: BL:50