FS Property
Property ID:
0x23
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x7C ‘|’
Description:
This character is sent as the field separator to delimit additional data
(MagnePrint info, Device info, DUKPT info, etc.). If the value is 0 no
character is sent. If the value is in the range 1 – 127 then the equivalent
ASCII character will be sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
SS Track 1 ISO ABA Property
Property ID:
0x24
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x25 ‘%’
Description:
This character is sent as the track 1 start sentinel for cards that have track 1
encoded in ISO/ABA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
SS Track 2 ISO ABA Property
Property ID:
0x25
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x3B ‘;’
Description:
This character is sent as the track 2 start sentinel for cards that have track 2
encoded in ISO/ABA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.