Pre card string property, Post card string property – MagTek iDynamo MagneSafe V5 User Manual
Page 27

Section 2. Communications
21
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
Pre Card String Property
Property ID:
0x1E
Property Type:
String
Length:
0 – 7 bytes
Get Property:
Yes
Set Property:
Yes
Default Value:
The default value is no string with a length of zero.
Description:
The value is an ASCII string that represents the reader’s pre card string. This
string can be 0 – 7 bytes long. This string is sent prior to all other card data.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
Example Set Pre-Card String property Request (Hex):
Cmd Num
Data Len
Prp ID
Prp Value
01
04
1E
31 32 33
Example Set Pre-Card String property Response (Hex):
Result Code Data Len
Data
00
00
Example Get Pre-Card String property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
1E
Example Get Pre-Card String property Response (Hex):
Result Code Data Len
Prp Value
00
03
31 32 33
Post Card String Property
Property ID:
0x1F
Property Type:
String
Length:
0 – 7 bytes
Get Property:
Yes
Set Property:
Yes
Default Value:
The default value is no string with a length of zero.
Description:
The value is an ASCII string that represents the reader’s post card string. This
string can be 0 – 7 bytes long. This string is sent after all other card data.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.
Example Set Post-Card String property Request (Hex):