beautypg.com

Magnesafe version number property, Track id enable property – MagTek iDynamo MagneSafe V5 User Manual

Page 21

background image

Section 2. Communications

15


Example Set Device Serial Number property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Device Serial Number property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

03

Example Get Device Serial Number property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33


MagneSafe Version Number Property

Property ID:

0x04

Property Type:

String

Length:

0 – 7 bytes

Get Property:

Yes

Set Property:

No

Default Value:

“V05” (may change later)

Description:

This is a maximum 7-byte read-only property that identifies the MagneSafe
Feature Level supported on this reader. Attempts to set this property will fail
with RC=01.


Example Get MagneSafe Version Number property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

04


Example Get MagneSafe Version Number property Response (Hex):

Result Code Data Len

Prp Value

00

02

56 30 35


Track ID Enable Property

Property ID:

0x05

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x95

Description:

This property is defined as follows:

id

0

T

3

T

3

T

2

T

2

T

1

T

1


Id

0 – Decodes standard ISO/ABA cards only

1 – Decodes AAMV and 7-bit cards also
If this flag is set to 0, only tracks that conform to the ISO format allowed for that
track will be decoded. If the track cannot be decoded by the ISO method it will
be considered to be in error.


T

#

00 – Track Disabled