SWB PARAMETERS
The SWB functions are listed in Table 4-2 and described below.
Control Characters and MICR Data
Control Characters may be added to the MICR data message. The characters are always in the
following locations:
The control characters, descriptions, and hex values are shown in Table 4-3.
Table 4-3. Control Characters
CONTROL
CHARACTER
DESCRIPTION
HEX VALUE
Start of Text
02
1B
End of Text
03
Return
0D
Feed
0A
For example, if
like this:
MICR Data:
Control Characters and Card Data
The control characters are also available for card data but they are applied to each track
individually. For example, if the
message is transmitted as follows:
Card Data:
Communication Modes
The selection of comm modes is a quick way of selecting multiple Control Characters. For
instance, to send a carriage return/line feed pair after the data, you can specify Comm Mode 3.
Comm Mode 7, also known as Packet Mode, calculates an LRC (Longitudinal Redundancy
Check), and appends it to the data message. Also, if a