11 instructions for exceptional operation, 2 how to change communication mode – Videotec ULISSE PLUS NETCAM User Manual
Page 41

Instruc
tions manual - English - EN
39
11 Instructions for
exceptional operation
11.1 How to switch from ONVIF
communication mode to RS-485
(telemetry) mode
The P&T is by default set to communicate via ONVIF
protocol.
11.2 How to change
communication mode
Turn off the P&T.
Set the dip switches (7.3 Configuration, page 28).
Follow the procedure as shown:
baud rate: 38400 (ON ON ON OFF)
Protocol: MACRO (OFF OFF OFF OFF OFF ON ON ON)
Serial communication and telemetry address: RS-
485 half-duplex, address 1 (ON ON OFF OFF OFF
OFF OFF ON)
Turn on the P&T.
Set the browser address to
pc.cgi.
Fig. 79
Change product part number: symbol N is replaced
by symbol Y. Example: From UPT2SVUAN00E to
UPT2SVUAY00E.
Click Send. Allow product restart.
Set the browser address to
pc.cgi to verify that the product part number was
actually changed. In case of failure repeat the
procedure from the beginning.
Turn off the P&T.
Switch the dip switches to OFF.
Fig. 80
Set the serial communication of the P&T as required
by the camera. Set the serial communication dip
switches. (7.3 Configuration, page 28).
Connect the serial port of the camera to the P&T
connector.
Fig. 81
Grey: RS-485 +. Pink: RS-485 -.
Power the camera.
F1
F2
A
B
+12V
GND
GND +12Vdc
Fig. 82
Turn on the P&T.
The P&T is now configured to communicate via serial
telemetry (RS-485).