Pc control command reference guide – Kenwood TS-990S User Manual
Page 9

– 8 –
PC Control Command referenCe guide
BS1
Scope Image Type
Parameters:
P1
0: Bandscope
1: Bandscope with Waterfall
2: Audio Scope
• There are times when the transceiver screen display cannot
be changed (corresponding to the operating conditions of the
[SCP] key).
• In some cases, the scope display may be temporarily
displaying a different screen. However, the response does not
change, even in that case.
Set
1
2
3
4
5
6
7
8
9
10
B
S
1
P1
;
Read
1
2
3
4
5
6
7
8
9
10
B
S
1
;
Answer
1
2
3
4
5
6
7
8
9
10
B
S
1
P1
;
BS2
Bandscope Object
Parameters:
P1
0: Main Band
1: Sub Band
Set
1
2
3
4
5
6
7
8
9
10
B
S
2
P1
;
Read
1
2
3
4
5
6
7
8
9
10
B
S
2
;
Answer
1
2
3
4
5
6
7
8
9
10
B
S
2
P1
;
BS3
Bandscope Operation Mode
Parameters:
P1
0: Center Mode
1: Fixed Mode
2: Keeping the scope range from Center mode to Fix mode
(Setting command only)
Set
1
2
3
4
5
6
7
8
9
10
B
S
3
P1
;
Read
1
2
3
4
5
6
7
8
9
10
B
S
3
;
Answer
1
2
3
4
5
6
7
8
9
10
B
S
3
P1
;
BS4
Bandscope Span (Center Mode)
Parameters:
P1
0: ±2.5 kHz
1: ±5 kHz
2: ±10 kHz
3: ±25 kHz
4: ±50 kHz
5: ±100 kHz
6: ±250 kHz
(Entering a value of 9 results in the initial value being entered.)
Set
1
2
3
4
5
6
7
8
9
10
B
S
4
P1
;
Read
1
2
3
4
5
6
7
8
9
10
B
S
4
;
Answer
1
2
3
4
5
6
7
8
9
10
B
S
4
P1
;
BS5
Bandscope Lower/Upper Frequency Limit (Fixed Mode)
Parameters:
P1 (Lower Limit Frequency)
8 digit frequency in Hz (unused digits must be 0)
P2 (Upper Limit Frequency)
8 digit frequency in Hz (unused digits must be 0)
Read
1
2
3
4
5
6
7
8
9
10
B
S
5
;
Answer
1
2
3
4
5
6
7
8
9
10
B
S
5
P1
P1
P1
P1
P1
P1
P1
11
12
13
14
15
16
17
18
19
20
P1
P2
P2
P2
P2
P2
P2
P2
P2
;
BS6
Bandscope Display Pause
Parameters:
P1
0: Pause OFF
1: Pause ON
Set
1
2
3
4
5
6
7
8
9
10
B
S
6
P1
;
Read
1
2
3
4
5
6
7
8
9
10
B
S
6
;
Answer
1
2
3
4
5
6
7
8
9
10
B
S
6
P1
;