beautypg.com

Pc control command reference guide – Kenwood TS-990S User Manual

Page 29

background image

– 28 –

PC Control Command referenCe guide

FA

Main Band Frequency

Parameters:

P1

Frequency (11 digits in Hz)

(For example, enter 00014195000 for 14.195 MHz. (Blank digits

must be entered as 0.) When calling an unregistered Memory

Channel, the response is all spaces.)

• You can set the frequency even while in Memory Channel

mode, except when on an unassigned channel.

• When configuring a standard channel, the frequency is

temporarily variable.

• Configuration is possible when the frequency is within a section

defined channel.

• The frequency set with this command is the frequency before

RIT/XIT is added.

Set

1

2

3

4

5

6

7

8

9

10

F

A

P1

P1

P1

P1

P1

P1

P1

P1

11

12

13

14

15

16

17

18

19

20

P1

P1

P1

;

Read

1

2

3

4

5

6

7

8

9

10

F

A

;

Answer

1

2

3

4

5

6

7

8

9

10

F

A

P1

P1

P1

P1

P1

P1

P1

P1

11

12

13

14

15

16

17

18

19

20

P1

P1

P1

;

FB

Sub Band Frequency

Parameters:

P1

Frequency (11 digits in Hz)

(For example, enter 00014195000 for 14.195 MHz. (Blank digits

must be entered as 0.) When calling an unregistered Memory

Channel, the response is all spaces.)

• You can set the frequency even while in Memory Channel

mode, except when on an unassigned channel.

• When configuring a standard channel, the frequency is

temporarily variable.

• Configuration is possible when the frequency is within a section

defined channel.

• The frequency set with this command is the frequency before

RIT/XIT is added.

Set

1

2

3

4

5

6

7

8

9

10

F

B

P1

P1

P1

P1

P1

P1

P1

P1

11

12

13

14

15

16

17

18

19

20

P1

P1

P1

;

Read

1

2

3

4

5

6

7

8

9

10

F

B

;

Answer

1

2

3

4

5

6

7

8

9

10

F

B

P1

P1

P1

P1

P1

P1

P1

P1

11

12

13

14

15

16

17

18

19

20

P1

P1

P1

;

FC

Change the Frequency (Tuning Control)

Parameters:

P1

0: Main Band

1: Sub Band

P2

0: Up

1: Down

P3

0: Normal frequency step size

1: Double the frequency step size

2: 5 times the frequency step size

3: 10 times the frequency step size

4: 50 times the frequency step size

5: 100 times the frequency step size

Set

1

2

3

4

5

6

7

8

9

10

F

C

P1

P2

P3

;

FL0

Select the Receive Filter

Parameters:

P1

0: Main Band

1: Sub Band

P2

0: A

1: B

2: C

Set

1

2

3

4

5

6

7

8

9

10

F

L

0

P1

P2

;

Read

1

2

3

4

5

6

7

8

9

10

F

L

0

P1

;

Answer

1

2

3

4

5

6

7

8

9

10

F

L

0

P1

P2

;