beautypg.com

Pc control command reference guide – Kenwood TS-990S User Manual

Page 34

background image

– 33 –

PC Control Command referenCe guide

IP3

ID and Password Management

Parameters:

P1

1 ~ 8: Character string length of current ID

P2

1 ~ 8: Character string length of current password

P3

1 ~ 8: Character string length of new ID

P4

1 ~ 8: Character string length of new password

P5

Up to 8 digits: Current ID

P6

Up to 8 digits: Current password

P7

Up to 8 digits: New ID

P8

Up to 8 digits: New password

P9

0: Update failed

1: Update successful

(If the current ID and password do not match, the update fails.)

Set

1

2

3

4

5

6

7

8

9

10

I

P

3

P1

P2

P3

P4

P5

P5

P5

11

12

13

14

15

16

17

18

19

20

P5

P5

P5

P5

P5

P6

P6

P6

P6

P6

21

22

23

24

25

26

27

28

29

30

P6

P6

P6

P7

P7

P7

P7

P7

P7

P7

31

32

33

34

35

36

37

38

39

40

P7

P8

P8

P8

P8

P8

P8

P8

P8

;

Read

1

2

3

4

5

6

7

8

9

10

I

P

3

P9

;

KS

Keying speed

Parameters:

P1

004 ~ 060 (in steps of 1)

Set

1

2

3

4

5

6

7

8

9

10

K

S

P1

P1

P1

;

Read

1

2

3

4

5

6

7

8

9

10

K

S

;

Answer

1

2

3

4

5

6

7

8

9

10

K

S

P1

P1

P1

;

KY

CW Keying

Parameters:

P1

For Setting 1, always enter a space.

For Setting 2, entering 0 will cause Setting 1 to stop. An error

will occur if any value other than 0 is entered.

0: Character buffer space

1: No character buffer space

P2

Enter a character string for keying.

The characters listed in the following table can be entered.

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

a

b

c

d

e

f

g

h

i

j

k

l

m

n

o

p

q

r

s

t

u

v

w

x

y

z

0

1

2

3

4

5

6

7

8

9

(space)

'

"

(

)

*

+

,

.

/

:

=

?

@

Using abbreviations, you can enter the following symbols:

Abbreviation

Symbol

Abbreviation

Symbol

BT

[

SK

>

AR

_

KN

]

AS

<

BK

\

HH

#

SN

%

• Parameter P2 has a fixed length of 24 bits. Characters that

are left blank will be filled with spaces, but these spaces will

not be converted to morse code. You can, however, prepare

an internal buffer that will allow you to send 25 or more

characters.

• Although you can use lower-case letters as well as upper-

case letters for the P2 parameter, there is no distinction made

between them when sending the morse code.

• You cannot enter a semicolon (;) for the P2 parameter.

Set 1

1

2

3

4

5

6

7

8

9

10

K

Y

P1

P2

P2

P2

P2

P2

P2

P2

11

12

13

14

15

16

17

18

19

20

P2

P2

P2

P2

P2

P2

P2

P2

P2

P2

21

22

23

24

25

26

27

28

29

30

P2

P2

P2

P2

P2

P2

P2

;

Set 2

1

2

3

4

5

6

7

8

9

10

K

Y

P1

;

Read

1

2

3

4

5

6

7

8

9

10

K

Y

;

Answer

1

2

3

4

5

6

7

8

9

10

K

Y

P1

;