beautypg.com

Eqt0, Eqt1, Eqt2 – Kenwood TS-990S User Manual

Page 21: Pc control command reference guide

background image

– 20 –

PC Control Command referenCe guide

EQT0

Transmission Equalizer

Parameters:

P1

0: OFF

1: ON

• The setting command is effective for the selected transmit

mode.

Set

1

2

3

4

5

6

7

8

9

10

E

Q

T

0

P1

;

Read

1

2

3

4

5

6

7

8

9

10

E

Q

T

0

;

Answer

1

2

3

4

5

6

7

8

9

10

E

Q

T

0

P1

;

EQT1

Transmission Equalizer Effect

Parameters:

P1

0: Hight Boost 1

1: High Boost 2

2: Format Pass

3: Bass Boost 1

4: Bass Boost 2

5: Conventional

6: User 1

7: User 2

8: User 3

• The setting command is effective for the selected transmit

mode.

• Use the UT command for equalizing of the chosen effect.

Set

1

2

3

4

5

6

7

8

9

10

E

Q

T

1

P1

;

Read

1

2

3

4

5

6

7

8

9

10

E

Q

T

1

;

Answer

1

2

3

4

5

6

7

8

9

10

E

Q

T

1

P1

;

EQT2

Transmission Equalizer Copy

Parameters:

P1

0: User 1

1: User 2

2: User 3

• The adjustment contents in the effect which are currently being

selected are copied first.

Set

1

2

3

4

5

6

7

8

9

10

E

Q

T

2

P1

;

EX

Set or Read the Menu

Parameters:

P1

0: Menu

1: Advanced Menu

P2

00 ~ 99: Category Number

(Entering a non-existing number causes an error to occur. Enter

any value when using the Advanced Menu.)

P3

00 ~ 99: Entry Number

(Entering a non-existing number causes an error to occur.

Entering a number that cannot be set also causes an error to

occur.)

P4 (Configuration Classification)

Space: Normal Configuration (Response is always a space.)

9: Initializing

P5

String of alphanumeric characters for the Menu setting

(Entering a value larger than the size limit causes an error to

occur.)

• Normally a 3-digit number (blank digits must be entered as

0).

• PF key settings use 4 digits (refer to the PF key allotment

ID lists).

• Frequency settings use 8 digits (blank digits must be entered

as 0).

• A power-on message can vary in length from 0 to 15

characters.

• Screen saver text can vary in length from 0 to 10 characters.

(Refer to the Menu tables below for the EX Command Parameter

lists. Entering a value other than the listed values causes an error

to occur.)

Set

1

2

3

4

5

6

7

8

9

10

E

X

P1

P2

P2

P3

P3

P4

P5 P5

11

12

13

14

15

16

17

18

19

20

P5

P5

P5

P5

P5

P5

P5

P5

P5

P5

21

22

23

24

25

26

27

28

29

30

P5

P5

P5

;

Read

1

2

3

4

5

6

7

8

9

10

E

X

P1

P2

P2

P3

P3

;

Answer

1

2

3

4

5

6

7

8

9

10

E

X

P1

P2

P2

P3

P3

P4

P5 P5

11

12

13

14

15

16

17

18

19

20

P5

P5

P5

P5

P5

P5

P5

P5

P5

P5

21

22

23

24

25

26

27

28

29

30

P5

P5

P5

;