Pc control command reference guide – Kenwood TS-990S User Manual
Page 32

– 31 –
PC Control Command referenCe guide
IF
Read the Transceiver Status
Parameters:
P1
11-digit displayed frequency of the Main band (for example,
00014175000 is 14.175 MHz)
(When calling an unregistered Memory Channel, the response
consists of all spaces.)
P2
Spaces (5)
P3
RIT/XIT frequency ±9990 Hz
P4
0: RIT OFF
1: RIT ON
P5
0: XIT OFF
1: XIT ON
P6, P7
Main band Memory Channel number (refer to the MC
command)
P8
0: Always 0
P9
Main band operating mode (refer to the MD command)
P10
Function (refer to the FR/FT commands)
P11
0: Always 0
P12
0: Simplex operation
1: Split operation
P13
0: Always 0
P14
00: Always 00
P15
0: Always 0
• While the Auto Information (AI) function is ON, a response is
automatically sent when the RIT/XIT frequency is changed.
Read
1
2
3
4
5
6
7
8
9
10
I
F
;
Answer
1
2
3
4
5
6
7
8
9
10
I
F
P1
P1
P1
P1
P1
P1
P1
P1
11
12
13
14
15
16
17
18
19
20
P1
P1
P1
P2
P2
P2
P2
P2
P3
P3
21
22
23
24
25
26
27
28
29
30
P3
P3
P3
P4
P5
P6
P7
P7
P8
P9
31
32
33
34
35
36
37
38
39
40
P10 P11 P12 P13 P14 P14 P15
;
IP0
DHCP
Parameters:
P1
0: DHCP OFF
1: DHCP ON
P2 ~ P5
001.001.001.001 ~ 223.223.223.223: IP address (If no IP
address is acquired when DHCP is turned ON, the IP address is
replaced with hyphens: ---.---.---.---)
• When DHCP is ON, the IP address acquired automatically is
output as a response. When DHCP is OFF, the set fixed IP
address is output as a response.
Set
1
2
3
4
5
6
7
8
9
10
I
P
0
P1
;
Read
1
2
3
4
5
6
7
8
9
10
I
P
0
;
Answer
1
2
3
4
5
6
7
8
9
10
I
P
0
P1
P2
P2
P2
P3
P3
P3
11
12
13
14
15
16
17
18
19
20
P4
P4
P4
P5
P5
P5
;