beautypg.com

Pc control command reference guide – Kenwood TS-990S User Manual

Page 48

background image

– 47 –

PC Control Command referenCe guide

PS

Power ON/ OFF

Parameters:

P1

0: Power OFF

1: Power ON

2: Power Source OFF (end) during processing (response only)

3: Power Source ON (activate) during processing (response

only)

4: During timer recording preparations (response only)

5: During timer recording operation (response only)

6: During timer recording cancellation confirmation display

(response only)

• While the transceiver is in economical standby mode, you

cannot use this command to turn the power ON/OFF.

• When the transceiver is turned ON using this command, the

response command (PS1;) is output. The transceiver cannot

accept commands until activation is completed.

• During timer recording preparations, you cannot perform

setting commands.

• During timer recording operation, you cannot perform

commands other than ID, ME and PS.

Set

1

2

3

4

5

6

7

8

9

10

P

S

P1

;

Read

1

2

3

4

5

6

7

8

9

10

P

S

;

Answer

1

2

3

4

5

6

7

8

9

10

P

S

P1

;

PT

Side Tone/Pitch Frequency

Parameters:

P1

000 ~ 080: 300 Hz to 1100 Hz (in steps of 10 Hz)

Set

1

2

3

4

5

6

7

8

9

10

P

T

P1

P1

P1

;

Read

1

2

3

4

5

6

7

8

9

10

P

T

;

Answer

1

2

3

4

5

6

7

8

9

10

P

T

P1

P1

P1

;

QA

Quick Memory Channel Information

Parameters:

P1

0 ~ 9: Quick Memory Channel Number

P2

11-digit Main band frequency (Unused high-end digits will

become 0.)

(When no information is available for a paremeter, it is returned

as blank.)

P3

Main band mode (Refer to P2 of the MS command.)

(When no information is available for a paremeter, it is returned

as blank.)

P4

11-digit Sub band frequency (Unused high-end digits will

become 0.)

(When no information is available for a paremeter, it is returned

as blank.)

P5

Sub band mode (Refer to P2 of the MS command.)

(When no information is available for a paremeter, it is returned

as blank.)

P6

0: Simplex

1: Split

(When no information is available for a paremeter, it is returned

as blank.)

P7

0: Dual Recpection OFF

1: Dual Recpection ON

(When no information is available for a paremeter, it is returned

as blank.)

• Auto answer is not provided by the AI function.

Read

1

2

3

4

5

6

7

8

9

10

Q

A

P1

;

Answer

1

2

3

4

5

6

7

8

9

10

Q

A

P1

P2

P2

P2

P2

P2

P2

P2

11

12

13

14

15

16

17

18

19

20

P2

P2

P2

P2

P3

P4

P4

P4

P4 P4

21

22

23

24

25

26

27

28

29

30

P4

P4

P4

P4

P4

P4

P5

P6

P7

;

QD

Quick Memory All Delete

Parameters:

No parameters are used with this command.

• When the AI function is ON, a response is output when deleting

the Quick Memory.

• You cannot perform this command when Quick Memory mode

is OFF (an error occurs).

Set

1

2

3

4

5

6

7

8

9

10

Q

D

;

Read

1

2

3

4

5

6

7

8

9

10

Q

D

;