Pc control command reference guide – Kenwood TS-990S User Manual
Page 48

– 47 –
PC Control Command referenCe guide
PS
Power ON/ OFF
Parameters:
P1
0: Power OFF
1: Power ON
2: Power Source OFF (end) during processing (response only)
3: Power Source ON (activate) during processing (response
only)
4: During timer recording preparations (response only)
5: During timer recording operation (response only)
6: During timer recording cancellation confirmation display
(response only)
• While the transceiver is in economical standby mode, you
cannot use this command to turn the power ON/OFF.
• When the transceiver is turned ON using this command, the
response command (PS1;) is output. The transceiver cannot
accept commands until activation is completed.
• During timer recording preparations, you cannot perform
setting commands.
• During timer recording operation, you cannot perform
commands other than ID, ME and PS.
Set
1
2
3
4
5
6
7
8
9
10
P
S
P1
;
Read
1
2
3
4
5
6
7
8
9
10
P
S
;
Answer
1
2
3
4
5
6
7
8
9
10
P
S
P1
;
PT
Side Tone/Pitch Frequency
Parameters:
P1
000 ~ 080: 300 Hz to 1100 Hz (in steps of 10 Hz)
Set
1
2
3
4
5
6
7
8
9
10
P
T
P1
P1
P1
;
Read
1
2
3
4
5
6
7
8
9
10
P
T
;
Answer
1
2
3
4
5
6
7
8
9
10
P
T
P1
P1
P1
;
QA
Quick Memory Channel Information
Parameters:
P1
0 ~ 9: Quick Memory Channel Number
P2
11-digit Main band frequency (Unused high-end digits will
become 0.)
(When no information is available for a paremeter, it is returned
as blank.)
P3
Main band mode (Refer to P2 of the MS command.)
(When no information is available for a paremeter, it is returned
as blank.)
P4
11-digit Sub band frequency (Unused high-end digits will
become 0.)
(When no information is available for a paremeter, it is returned
as blank.)
P5
Sub band mode (Refer to P2 of the MS command.)
(When no information is available for a paremeter, it is returned
as blank.)
P6
0: Simplex
1: Split
(When no information is available for a paremeter, it is returned
as blank.)
P7
0: Dual Recpection OFF
1: Dual Recpection ON
(When no information is available for a paremeter, it is returned
as blank.)
• Auto answer is not provided by the AI function.
Read
1
2
3
4
5
6
7
8
9
10
Q
A
P1
;
Answer
1
2
3
4
5
6
7
8
9
10
Q
A
P1
P2
P2
P2
P2
P2
P2
P2
11
12
13
14
15
16
17
18
19
20
P2
P2
P2
P2
P3
P4
P4
P4
P4 P4
21
22
23
24
25
26
27
28
29
30
P4
P4
P4
P4
P4
P4
P5
P6
P7
;
QD
Quick Memory All Delete
Parameters:
No parameters are used with this command.
• When the AI function is ON, a response is output when deleting
the Quick Memory.
• You cannot perform this command when Quick Memory mode
is OFF (an error occurs).
Set
1
2
3
4
5
6
7
8
9
10
Q
D
;
Read
1
2
3
4
5
6
7
8
9
10
Q
D
;