beautypg.com

En 39 – Siemens KI32LAD30 User Manual

Page 39

background image

en

39

Fault

Possible cause

Remedial action

The light

does not function.

The LED light

is defective.

See chapter “Light (LED)” section.

Appliance was open

too long.
Light is switched off

after approx. 10 min.

When the appliance is closed

and opened, the light is on again.

The frozen food is

frozen solid.

Loosen frozen food with a blunt

object. Do not use a knife or pointed

object.

There is a thick layer

of frost in the freezer

compartment.

Defrosting the freezer compartment

(see chapter Defrosting). Always

ensure that the freezer compartment

door is closed properly.

Bottom

of the refrigerator

compartment is wet.

The condensation

channel or drainage

hole are blocked.

Clean the condensation channel

and the drainage hole. See chapter

Cleaning the appliance. Fig. #

The temperature

in the refrigerator

compartment is too

cold.

Freezer compartment

door is open.

Close the freezer compartment

door. The freezer compartment door

engages audibly.

Temperature has been

set too low.

Increase the temperature.

The Super function is

switched on.

Switch off Super function.

The refrigerating unit

is switching on more

frequently and for

longer.

Appliance opened

frequently.

Do not open the appliance

unnecessarily.

The ventilation

openings have been

covered.

Remove obstacles.

Appliance is not

cooling, temperature

display and light

are lit.

Showroom mode is

switched on.

Hold down alarm button, Fig "/5,

for 10 seconds until

an acknowledgement signal sounds.
After a short time check whether

your appliance is cooling.

This manual is related to the following products: