beautypg.com

Installing and connecting the appliance, Observe ambient temperature and ventilation, Water connection – Siemens KA62DV71 User Manual

Page 26: Electrical connection, Aligning the appliance

background image

26

Observe ambient
temperature and
ventilation

Ambient temperature

The climatic class can be found on

the rating plate. It states the room

temperature within which the appliance

can be operated. The rating plate is

located in the refrigerator compartment

at the bottom right side.

Climatic class

Permitted ambient
temperature

SN

+10 °C to 32 °C

N

+16 °C to 32 °C

ST

+16 °C to 38 °C

T

+16 °C to 43 °C

Ventilation

Never cover the ventilation openings

on the rear of the appliance.
Otherwise the refrigerating unit must

work harder, increasing the power

consumption.
Place the enclosed spacers in the

designated holders on the back of the

appliance. This ensures that there is

a minimum distance between the

appliance and the wall.

Installing and
connecting
the appliance

S Have a technician install and connect

the appliance according to the

enclosed installation instructions.

S After installing the appliance, wait at

least 1 hour until the appliance starts

up. During transportation the oil in the

compressor may have flowed into the

refrigeration system.

S Before switching on the appliance for

the first time, clean the interior of the

appliance (see chapter Cleaning").

S Always connect the water before

the power.

S Apart from statutory national

regulations, you should stick to the

connection terms relating to the local

electricity and water companies.

S Do not remove the transportation

protection devices from the shelves

and storage compartments until the

appliance has been installed.

Water connection

The water may be connected only

by a competent fitter according to the

local regulations of the appropriate

water supply company.
Connect the appliance to a drinking

water line:
- Minimum pressure: 0.2 MPa (2 bar)
- Maximum pressure: up to 0.8 MPa

(8 bar)
Taste and odour of the water may be

improved by installing the enclosed

water filter. In this case observe the

different connection conditions

(see chapter Water filter").

Note
The maximum outside diameter of

the water mains (without connecting

pieces) is 10 mm.

Electrical connection

Do not use extension cables or

distributors. This appliance must be

connected to a permanently installed

socket.
The plug to secure the appliance

must be freely accessible.

Connect the appliance to

a 220-240 V/50 Hz ac current via

a plug which has been properly

installed. The socket must be fused

with a 10 to 16 A fuse or higher.
If the appliance is to be operated in

a nonĆEuropean country, check on

the rating plate whether the indicated

voltage and current type correspond

to the values of your mains supply.

The rating plate is situated in the

bottom rightĆhand side of the

appliance. The mains connection cable

may be replaced by an electrician only.

!

Warning!

Never connect the appliance to

electronic energy saver plugs

(e. g. Ecoboy: Sava Plug) or to power

inverters which convert the direct

current to 230 V alternating current

(e. g. solar equipment, power supplies

on ships).

Aligning the appliance

To ensure that the appliance functions

correctly, it must be set level with

a spirit level.
If the appliance is not level, water may

flow out of the ice maker, ice cubes

may be irregular or the doors may not

close properly.

S Place the appliance in the designated

location.

S Align front feet with a hexagon

wrench.

S Align front feet with an Allen key.

en

This manual is related to the following products: