Important, Manual reset hi-limit instructions – American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III User Manual
Page 47

43
IMPORTANT
MANUAL RESET HI-LIMIT INSTRUCTIONS
DUAL TIMER MODELS ONLY
This dryer was manufactured with a burner manual reset hi-limit thermostat, and a lint/basket (tumbler) manual
reset hi-limit thermostat. If either the manual reset hi-limit thermostat is open prior to the start of the drying
cycle, or during the cycle, the dryer will not recognize the open state of the burner hi-limit thermostat and will
start or continue through the drying cycle with no heat. Manual reset hi-limit thermostat must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner oven
operation. The location of the manual reset hi-limit switch is on the right side of the burner box.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N:114093