beautypg.com

H. preparation for operation/start-up – American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III User Manual

Page 32

background image

28

H. PREPARATION FOR OPERATION/START-UP

The following items should be checked before attempting to operate the dryer:

1. Read ALL “CAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.

2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to

the left side panel area behind the top control (access) door. In the case of 208 VAC or 230/240 VAC, the

supply voltage must match the electric service exactly.

3. GAS MODELS - check to assure that the dryer is connected to the type of heat/gas indicated on the dryer

data label.

4. GAS MODELS - the sail switch damper assembly was installed and adjusted at the factory prior to

shipping. However, each sail switch adjustment must be checked to assure that this important safety

control is functioning.

5. GAS MODELS - be sure that ALL gas shutoff valves are in the open position.

6. Be sure ALL back panels (guards) and electric box covers have been replaced.

7. Check ALL service doors to assure that they are closed and secured in place.

8. Be sure the lint door is securely in place.

9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely.

10. Check bolts, nuts, screws, terminals, and fittings for security.

11. Check basket (tumbler) bearing setscrews to insure they are ALL tight.