28
H. PREPARATION FOR OPERATION/START-UP
The following items should be checked before attempting to operate the dryer:
1. Read ALL CAUTION, WARNING, and DIRECTION labels attached to the dryer.
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to
the left side panel area behind the top control (access) door. In the case of 208 VAC or 230/240 VAC, the
supply voltage must match the electric service exactly.
3. GAS MODELS - check to assure that the dryer is connected to the type of heat/gas indicated on the dryer
data label.
4. GAS MODELS - the sail switch damper assembly was installed and adjusted at the factory prior to
shipping. However, each sail switch adjustment must be checked to assure that this important safety
control is functioning.
5. GAS MODELS - be sure that ALL gas shutoff valves are in the open position.
6. Be sure ALL back panels (guards) and electric box covers have been replaced.
7. Check ALL service doors to assure that they are closed and secured in place.
8. Be sure the lint door is securely in place.
9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely.
10. Check bolts, nuts, screws, terminals, and fittings for security.
11. Check basket (tumbler) bearing setscrews to insure they are ALL tight.