beautypg.com

Timing legend, Reversing timer spin/dwell adjustments – American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III User Manual

Page 41

background image

37

SECTION VII

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left

rear area of the dryer.

Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches

located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Adjustment Position Number

1

2

3

4

5

Time in Seconds*

30

60

90

120

150

DWELL (STOP) TIME

Adjustment Position Number

1

2

3

4

5

Time in Seconds*

5

6.3

7.6

8.9

10.2

* Values shown are +/- 1-second.