I. PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test

should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or

due to marginal location (installation) conditions.

1. Turn on electric power to the dryer.

a. Open ALL shutoff valves (gas models only)

2. Refer to the Operating Instructions for starting your particular model dryer.

a. Gas Dryers

1) When a gas dryer is first started (during initial start-up), the burner has a tendency not to ignite on

the first ignition attempt. This is because the gas supply piping is filled with air, so it may take a few

minutes for the air to be purged from the lines.

NOTE: During the purging period, check to be sure that ALL gas shutoff valves are open.

NOTE: Gas dryers are equipped with a Hot Surface Ignition (HSI) system, which has internal

diagnostics. If ignition is not established within the first attempt, the heat circuit in the HSI

module will “LOCKOUT” until it is manually reset. To reset the HSI system, open and close

the main door and restart the dryer.

2) A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the

water column (W.C.) pressure is correct and consistent.

NOTE: Water column pressure requirements (measured at the gas valve pressure tap):

Natural Gas--------------------3.5 Inches (8.7 mb) Water Column.

Liquid Propane (L.P.) Gas ---10.5 Inches (26.1 mb) Water Column.

IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be

regulated at the source (L.P. tank), or an external regulator must be added to each

dryer.

3. Make a complete operational check of ALL safety related circuits:

a. Door Switch(es)

b. Hi-Limit Thermostats

c. Sail Switch (for gas models only)