SECTION X

BURNER AND BASKET (TUMBLER)/LINT CHAMBER

MANUAL RESET HI-LIMIT INSTRUCTIONS

IMPORTANT

MANUAL RESET HI-LIMIT INSTRUCTIONS

FOR PHASE 7 MODELS

This dryer was manufactured with a manual reset burner hi-limit and basket (tumbler)/lint chamber hi-limit

thermostat which is monitored by the Phase 7 computer. If the burner is open prior to start of the drying cycle, the

dryer will start momentarily and then shut down, the Phase 7 computer will display “BURNER HIGH LIMIT

FAULT” with an audio indication. If the basket (tumbler)/lint chamber hi-limit thermostat is open prior to start,

the display will read “EXHAUST HIGH LIMIT FAULT” with an audio indication as well.

If either manual reset hi-limit thermostat opens during a drying cycle, the display will show the applicable error

code described above, along with an audio indication. If the drum temperature is above 100° F (38° C), the dryer

will continue to run with no heat for 3 minutes or until the drum temperature has dropped below 100° F (38° C).

The clear/stop button on the Phase 7 keyboard (touch pad) must be pressed to clear the error condition. The

open manual reset hi-limit thermostat must be reset “manually” prior to the start of the next cycle.

This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner operation.

The location of the burner hi-limit is on the right side of the burner box and the basket (tumbler) hi-limit is located

in the lint chamber area.

WARNING: Discontinue power to dryer before attempting to reset hi-limit.

IMPORTANT

This dryer is equipped with a burner

hi-limit and tumbler/lint chamber hi-limit

thermostat which must be reset manually.

WARNING: Discontinue power to dryer

before attempting to reset hi-limit.

ADC P/N:114093