beautypg.com

Type of gas, Typ e of gas – American Dryer Corp. Gas HSI - Phase 7/FSS AD-78 III User Manual

Page 29

background image

25

2. Technical Gas Data

a. Gas Specifications

b. Gas Connections

Inlet connection -------- 3/4” N.P.T.

Inlet supply size -------- 3/4” N.P.T. (minimum)

Btu/hr input-------------- 204,000 (51,408 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure

must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches

(29.9 mb) water column (W.C.) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so

that the gas pressure must be regulated upstream of the dryer. The pressure measured at each

gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no

regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at

the source (L.P. tank) or an external regulator must be added to each dryer.

* Drill Material Size (D.M.S.) equivalents are as follows:

Natural Gas ------------- #23 = 0.1540” (3.9116 mm).

Liquid Propane Gas ---- #42 = 0.0935” (2.3749 mm).

TYPE OF GAS

NATURAL

LIQUID PROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

Shaded areas are stated in metric equivalents

TYP E OF GAS

Liquid Propane

Conversion Kit

Part

Number

ADC

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty. D.M.S.*

Part

Number

Qty. D.M.S.*

Part

Number

ADG-78

III

204,000

51,408

3

#23

140856

3

#42

140810

881655