Pv100, Valve controller – High Country Tek ProValve 100 Series User Manual
Page 12
021-PV100 Rev A
PV100 User Manual
12
Copyright © High Country Tek, Inc.
– 2013
PV100
Valve Controller
RAMP UP HIGH - Sets the time to ramp the output from low speed to high speed. This parameter applies only to
two-speed modes. The Ramp Up High parameter is variable.
RAMP DOWN HIGH - Sets the time to ramp the output from high speed to low speed. This parameter applies only
to two-speed modes. The Ramp Down High parameter is variable.
RAMP DOWN LOW - Sets the time to ramp the output from low speed to off. This parameter applies only to two-
speed modes. The Ramp Down Low parameter is variable.
OUTPUT CURRENT - Displays the present output current. This parameter is a monitor type.
SUPPLY VOLTAGE - Displays the
module’s power supply voltage. It is helpful for troubleshooting. This parameter
is a monitor type.
FAULT STATUS - The Fault LED displays solid red for faults: Open Output, Voltage Drop and Low
–10V Supply.