Parameter list, Pv100, Valve controller – High Country Tek ProValve 100 Series User Manual
Page 10
021-PV100 Rev A
PV100 User Manual
10
Copyright © High Country Tek, Inc.
– 2013
PV100
Valve Controller
Parameter List
The following table outlines the PV100 parameters as well as the limits and units of measure for each parameter.
Parameter
Limits
Units
PV100
Version #
Mode A1, D1, D2, D3
0 to 7
Mode #
A Minimum input
-100 to 100
%
A Maximum input
-100 to 100
%
A Minimum output
0.01 to 2.50
*
A
A Low/Over output
0.01 to 2.50
*
A
A Maximum output
0.01 to 2.50
*
A
B Minimum input
-100 to 100
%
B Maximum input
-100 to 100
%
B Minimum output
0.01 to 2.50
*
A
B Low/Over output
0.01 to 2.50
*
A
B Maximum output
0.01 to 2.50
*
A
Dither frequency
35, 41, 49, 61, 81, 122, 244
(select OFF for PWM frequency 15.63KHz)
Hz
Input slew time
0.0 to 30.0
Seconds
Ramp up low
0.10 to 16.96
Seconds
Ramp up high
0.10 to 16.96
Seconds
Ramp down high
0.10 to 16.96
Seconds
Ramp down low
0.10 to 16.96
Seconds
Output current
A
Supply voltage
Volts
Fault status
Fault
*
0 to 500mA for
–L version, 0 to 250mA for –N version