MVP-Cxx-(D1)
Valve Controller
Configuration
The GUI has 4 buttons (ran from a PC): Lock, Unlock, Up, and Down. There are short-cut keys:
‘/’(lock), ‘*’(unlock),
‘+’(up), and ‘-‘(down).
The HCT Hand Held Interface has the same 4 buttons and 2-line LCD.
Use the up and down arrows to navigate through the parameter list. The display will show the next parameter in the
list when pressed. The parameter name is on the first line and the value is on the second line. The list is in circular,
stepping down from the last parameter to the first and vice-versa.
There are three types of parameters: fixed; monitor; and variable. Fixed parameters show the mod
ule’s firmware
version, etc. Monitor parameters display output current and system voltage. Use variable parameters to configure
the controller, such as maximum output current, operating mode, etc. Some parameters combine variable and
monitor in one line. Use it to set a variable according to the current monitor value.
Press the unlock button to enter the edit mode. An asterisk (*) will appear at the beginning of the second line. Use
the up and down buttons to change the value. For parameters containing both variable and monitor, the monitor
data is in square brackets.
Press the lock button to save the parameters and end edit mode.
When the lock button is pressed, the changes take effect immediately. Change values only when the machine is
NOT
running.