beautypg.com

Dual-coil valve control, Mvp-cxx-(d1), Valve controller – High Country Tek MVP-C Series User Manual

Page 19: Mvpc/d1

background image

021-MVP-Cxx-(D1) Rev A

MVP-C-(D1) User Manual

19

Copyright © High Country Tek, Inc.

– 2013

MVP-Cxx-(D1)

Valve Controller

Dual-coil Valve Control

Two MVPs can drive a dual-coil valve with a signal of 0-5VDC, or 0-10VDC, or 4-20mA.

If enable switch is not used, set MVP #1 to be Mode 1, MVP #2 to be Mode 2.

If enable switch is used, set MVP #1 to be Mode 3, MVP #2 to be Mode 4.

Set 2.5-5VDC for MVP #1, 7.5-10VDC for MVP #2 when there is no deadband in the command input. Normally we
leave deadband in the middle and both ends.

Set the dither and output settings according to the valve specifications.

FUSE

+V Power Input
9 - 28VDC

+V = Enabled

Brown PWR +

MVPC/D1

Electronic Valve

Controller

White Enable

GRN/YEL

+5VDC @ 2mA

0-5VDC

Red Ref. Out

BLK Analog I/P

Blue GND

V

D

C

I/

P

m

A

I/

P

0-10VDC

V

D

C

I/

P

4-20mA

Connector GND

Screen

+V = Enabled

Brown PWR +

MVPC/D1

Electronic Valve

Controller

White Enable

GRN/YEL

Prop. PWM
(Sourcing)

+5VDC @ 2mA

0-5VDC

Red Ref. Out

BLK Analog I/P

Blue GND

Connector GND

Screen

Prop. PWM
(Sourcing)

Min

(MVP #1)

Coil

A

max

Coil

B

min

Coil

B

max

Coil

A

min

Center (5V)

Coil

A

Current

0

Coil

B

Current

10V

Max

(MVP #2)

Command

Input

Max

(MVP #1)

Min

(MVP #2)