Dual-coil valve control, Mvp-cxx-(d1), Valve controller – High Country Tek MVP-C Series User Manual
Page 19: Mvpc/d1
021-MVP-Cxx-(D1) Rev A
MVP-C-(D1) User Manual
19
Copyright © High Country Tek, Inc.
– 2013
MVP-Cxx-(D1)
Valve Controller
Dual-coil Valve Control
Two MVPs can drive a dual-coil valve with a signal of 0-5VDC, or 0-10VDC, or 4-20mA.
If enable switch is not used, set MVP #1 to be Mode 1, MVP #2 to be Mode 2.
If enable switch is used, set MVP #1 to be Mode 3, MVP #2 to be Mode 4.
Set 2.5-5VDC for MVP #1, 7.5-10VDC for MVP #2 when there is no deadband in the command input. Normally we
leave deadband in the middle and both ends.
Set the dither and output settings according to the valve specifications.
FUSE
+V Power Input
9 - 28VDC
+V = Enabled
Brown PWR +
MVPC/D1
Electronic Valve
Controller
White Enable
GRN/YEL
+5VDC @ 2mA
0-5VDC
Red Ref. Out
BLK Analog I/P
Blue GND
V
D
C
I/
P
m
A
I/
P
0-10VDC
V
D
C
I/
P
4-20mA
Connector GND
Screen
+V = Enabled
Brown PWR +
MVPC/D1
Electronic Valve
Controller
White Enable
GRN/YEL
Prop. PWM
(Sourcing)
+5VDC @ 2mA
0-5VDC
Red Ref. Out
BLK Analog I/P
Blue GND
Connector GND
Screen
Prop. PWM
(Sourcing)
Min
(MVP #1)
Coil
A
max
Coil
B
min
Coil
B
max
Coil
A
min
Center (5V)
Coil
A
Current
0
Coil
B
Current
10V
Max
(MVP #2)
Command
Input
Max
(MVP #1)
Min
(MVP #2)