MVP-Cxx-(D1)
Valve Controller
MVP-Cxx - The title parameter is fixed. It displays the model number and the firmware version.
MODE - Six modes of operation.
1. Output is proportional to the command input with Enable not used.
2. Output is inversely proportional to the command input with Enable not used.
3. Output is proportional to the command input with Enable used.
4. Output is inversely proportional to the command input with Enable used.
5. 2-speed where Enable provides output at the level set in Minimum Output and Command provides output
at the level set in Maximum Output.
6. 2-speed where Enable provides output at the level set in Maximum Output and Command provides output
at the level set in Minimum Output.
MIN INPUT - Sets the minimum command input. The input can be inverted. The value in the brackets is the present
command input. This parameter is a combination variable/monitor type.
MAX INPUT - Sets the maximum command input. The input can be inverted. The value in the brackets is the
present command input. This parameter is a combination variable/monitor type.
MIN OUTPUT - Sets the minimum output current (milliamps for -06A, amps for -12A, -25A). It cannot be inverted.
The value in the square brackets is the present output current. This parameter is a combination
variable/monitor type.
MAX OUTPUT - Sets the maximum output current (milliamps for -06A, amps for -12A, -25A). It cannot be inverted.
The value in the square brackets is the present output current. This parameter is a combination
variable/monitor type.
RAMP UP/DOWN - Sets the time for Output current to ramp UP or Down through the full input range. These
parameters are variable.
DITHER FREQ.
– Set the PWM or dither frequency according to the valve specifications. This parameter is
variable.
Options: 30, 33, 38, 43, 50, 60, 75, 100, 150, 300, (Select OFF for 1000Hz) for MVP-C.
Options: 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, (Select OFF for 1000Hz) for MVP-Cxx-
xxx-D1.
OUTPUT CURRENT - Displays the present output current. This parameter is a monitor type.
SUPPLY VOLTAGE - Displays the
module’s power supply voltage. It is helpful for troubleshooting. This parameter
is a monitor type.
FAULT STATUS - The STATUS LED will flash red 2 times for Coil Open and 3 times for Coil Short.