AMETEK 1990 DN DeviceNet Resolver Interface Module User Manual
Page 8
8
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.com
Assembly #2 - Config Assembly
Byte
7
6
5
4
3
2
1
0
0
Setpoint 1 On Position (Low Byte)
1
Setpoint 1 On Position (High Byte)
2
Setpoint 1 Off Position (Low Byte)
3
Setpoint 1 Off Position (High Byte)
4
Setpoint 2 On Position (Low Byte)
5
Setpoint 2 On Position (High Byte)
6
Setpoint 2 Off Position (Low Byte)
7
Setpoint 2 Off Position (High Byte)
8
Setpoint 3 On Position (Low Byte)
9
Setpoint 3 On Position (High Byte)
10
Setpoint 3 Off Position (Low Byte)
11
Setpoint 3 Off Position (High Byte)
12
Setpoint 4 On Position (Low Byte)
13
Setpoint 4 On Position (High Byte)
14
Setpoint 4 Off Position (Low Byte)
15
Setpoint 4 Off Position (High Byte)
16
Setpoint 5 On Position (Low Byte)
17
Setpoint 5 On Position (High Byte)
18
Setpoint 5 Off Position (Low Byte)
19
Setpoint 5 Off Position (High Byte)
20
Setpoint 6 On Position (Low Byte)
21
Setpoint 6 On Position (High Byte)
22
Setpoint 6 Off Position (Low Byte)
23
Setpoint 6 Off Position (High Byte)
24
Setpoint 7 On Position (Low Byte)
25
Setpoint 7 On Position (High Byte)
26
Setpoint 7 Off Position (Low Byte)
27
Setpoint 7 Off Position (High Byte)
28
Setpoint 8 On Position (Low Byte)
29
Setpoint 8 On Position (High Byte)
30
Setpoint 8 Off Position (Low Byte)
31
Setpoint 8 Off Position (High Byte)
4.1.5: Format of I/O Assembly Data Attribute
Assembly #1 - I/O Assembly
Byte
7
6
5
4
3
2
1
0
0
Setpoint Status
1
Position Low
2
Position High
3
RPM Low
4
RPM High