AMETEK 1990 DN DeviceNet Resolver Interface Module User Manual
Page 12
12
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.AMETEKAPT.com
Parameter Instance #1 (Position)
Attribute ID
Access Rule
Name
Data Type
Value
1
Get
Parameter Value
UINT
Current Position
2
Get
Link Path Size
USINT
0x06
3
Get
Link Path
ARRAY
“0x20 0x64 0x24 0x01 0x30 0x01”
4
Get
Descriptor
WORD
0x0030
5
Get
Data Type
USINT
0x02
6
Get
Data Size
USINT
0x02
Parameter Instance #2 (Scale Factor)
Attribute ID
Access Rule
Name
Data Type
Value
1
Get/Set
Parameter Value
UINT
Current Scale Factor
2
Get
Link Path Size
USINT
0x06
3
Get
Link Path
ARRAY
“0x20 0x64 0x24 0x01 0x30 0x02”
4
Get
Descriptor
WORD
0x0000
5
Get
Data Type
USINT
0x02
6
Get
Data Size
USINT
0x02
Parameter Instance #3 (Direction)
Attribute ID
Access Rule
Name
Data Type
Value
1
Get/Set
Parameter Value
USINT
Current Direction
2
Get
Link Path Size
USINT
0x06
3
Get
Link Path
ARRAY
“0x20 0x64 0x24 0x01 0x30 0x03”
4
Get
Descriptor
WORD
0x0002
5
Get
Data Type
USINT
0x08
6
Get
Data Size
USINT
0x01
Parameter Instance #4 (RPM)
Attribute ID
Access Rule
Name
Data Type
Value
1
Get
Parameter Value
USINT
Current RPM Value
2
Get
Link Path Size
USINT
0x06
3
Get
Link Path
ARRAY
“0x20 0x66 0x24 0x01 0x30 0x01”
4
Get
Descriptor
WORD
0x0030
5
Get
Data Type
USINT
0x02
6
Get
Data Size
USINT
0x02