beautypg.com

American Dynamics ULTRA VIIE User Manual

Page 6

background image

SPEEDDOME ULTRA VIIE DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY

8200-0184-12, REV. A

OPERATOR’S MANUAL SUPPLEMENT

6 of 15

Figure 10.

3. Use the joystick to highlight Presets and press

Focus Far to select. The Select Preset To
Program
screen appears (Figure 11).

Figure 11.

4. Use the joystick to highlight Motion Detection

Setup and press Focus Far. The Motion
Detection Setup
screen appears (Figure 12).

Figure 12.

5. The PRESET number field is highlighted.

Press the Zoom In/Out button until the Preset
number you want to use for this motion
detection setup (1-96) appears.

6. Use the joystick to highlight the ZONE field.

Use the Zoom In/Out button until the zone
number (1-8) you want to apply to the Preset
appears.

7. Use the joystick to highlight the SENS field.

Use the Zoom In/Out button until the
sensitivity level you want to apply to your zone
appears. Note: Zone sensitivity ranges from
zero (no sensitivity) to five (high sensitivity).
Zero is used to disable individual zones on a
temporary basis.

8. Use the joystick to highlight the ACTION field.

Use the Zoom In/Out button until the action
you want appears. Action determines how the
system will respond when motion is detected.
Choices are:

No Action* - no action occurs
Preset (1-96) – calls a Preset
Pattern (1-16) – runs a Pattern
Output (1-4) – activates an output

*

When No Action is programmed on the motion

detection screen, the dome’s return to a Home
position is delayed as long as motion occurs within
the time specified on the return-to-home screen
.

9. Press

the

Focus Far button. The Motion

Detection Setup screen appears (Figure 13).

Figure 13.

10. Using the joystick, move the rectangular zone

indicator to a desired location and press Focus
Far
to save and exit. (Note: The rectangular
zone indicator does not appear on-screen until
the joystick is moved.)

11. Repeat steps 6-10 to create additional

detection zones (1-8).

12. When

the

Motion Detection Setup screen

appears, use the joystick to highlight EXIT and
press Focus In/Out to save.

ALARMS/AREAS/HOME/PRESETS/PZ

SET ALARM ACTIONS

SET ALARM STATES

SET HOME POSITION

SET NORTH POSITION

AREA BOUNDARIES

PRIVACY ZONES

PRESETS

SCAN LIMITS

EXIT

SELECT PRESET TO PROGRAM

PRESET PRESET

NAME

NUMBER
1-96

PRESET 1-96

MOTION DETECTION SETUP

SEQUENCE SETUP MENU

CAMERA FUNCTIONS

FOCUS FAR to program preset

EXIT

MOTION DETECTION SETUP

1 PRESET 1

ZONE SENS ACTION

1 0 NO

ACTION

XX

HIDE ALL ZONES

NO

DELETE ALL ZONES

FOCUS FAR to program zones

EXIT

MOTION DETECTION SETUP

PRESET 1

ZONE 4






ESC/FOCUS = save & exit