beautypg.com

Input connections, Output connections – Red Lion CSSG User Manual

Page 5

background image

5

-SIG

+SIG

COM

VDC+

VDC-

+SIG

-EXC

-SIG

+EXC

-SIG

+SIG

COM

+EXC

-EXC

-SIG

+EXC

-SIG

COM

+SIG

+EXC

+SIG

+SEN

-SEN

6-Wire Bridge Input

INPUT CONNECTIONS

4-Wire Bridge Input

2-Wire Single Ended Input

BRIDGE COMPLETION RESISTORS

For single strain gage applications, bridge completion resistors must be employed externally to the module. Only use metal film

resistors with a low temperature coefficient of resistance.

Load cells and pressure transducers are normally implemented as full resistance bridges and do not require bridge completion resistors.

OUTPUT CONNECTIONS

OP1 +

OP2 +

+SIG2 (OPT)

+EXC2 (OPT)

10

11
12

9

8

7

OP2 COM

OP1 COM

Load

Power

Power

OP3 N.O.

N/C

ANALOG+

ANALOG-

16

17

18

15

14

13

OP3 N.C.

OP3 COM

Power

Power

Load

or

OP3 N.C.

OP3 N.O.

OP3 COM

N/C

16

18

17

13

14

15

ANALOG-

ANALOG+

Recorder,
Controller,
Valve, etc

+

-

OP2 COM

+EXC2 (OPT)

+SIG2 (OPT)

OP2 +

OP1 +

10

12

11

78

9

OP1 COM

Load

+

-

Power +

-

Power

-
+

+

-

Outputs 1 and 2 - Relay Version

Outputs 1 and 2 - Solid State Version

Output 3

Analog Output