3 module 3 - d, Isplay, Ront – Red Lion LDT User Manual
Page 9: Anel, Arameters

9
The
selection allows the
SEL
key to toggle between the timer and cycle
counter displays.
FRONT PANEL DISPLAY SELECT ENABLE (SEL
)
5.3 MODULE 3 - D
ISPLAY
AND
F
RONT
P
ANEL
K
EY
P
ARAMETERS
(
)
PAR
Pro
Front Panel
Reset Enable
Front Panel
Display
Select
Display Scroll
Enable
Load Factory
Default
Settings
Programming
Security
Code
Display
Intensity
Level
3-dSP
SEL-En
rSt-En
ScroLL
d-LEV
CodE
FACSEt
PARAMETER MENU
The
selection allows the
RST
key to reset the selected value(s). The
shaded selections only appear if the cycle counter is enabled.
FRONT PANEL RESET ENABLE (RST
)
The
selection allows the display to automatically scroll between the
timer and cycle counter values. The scroll rate is about every 4 seconds.
DISPLAY SCROLL ENABLE
Enter the desired Display Intensity Level (1-5). The display will actively dim
or brighten as levels are changed.
DISPLAY INTENSITY LEVEL
The Security Code determines the programming mode and the accessibility
of programming parameters. This code can be used along with the Program
Mode Lock-out (
) in the User Input Function parameter (Module 1).
Two programming modes are available. Full Programming mode allows all
parameters to be viewed and modified. Quick Programming mode permits only
PROGRAMMING SECURITY CODE
The
selection will return the meter to the factory default settings. The
meter will display
and then return to
, at which time all settings have
been changed.
LOAD FACTORY DEFAULT SETTINGS
to
to
USER INPUT
FUNCTION
USER INPUT
STATE
SECURITY
CODE
FULL PROGRAMMING
MODE ACCESS
0
Full Programming
Immediate Access
not
______
1-99
Quick
Programming
100-999
prompt
With correct code entry
at
prompt *
0
Programming Lock
No Access
Active
1-99
Quick
Programming
No Access
100-999
prompt
With correct code entry
at
prompt *
Not Active
0-999
Full Programming
Immediate Access
After Quick Programming
with correct code entry
at
prompt *
* Entering Code 222 allows access regardless of security code.
the Setpoint values and Timer Stop value to be modified, but allows direct
access to these values without having to enter Full Programming mode.
Programming a Security Code other than 0, requires this code to be entered
at the
prompt in order to access Full Programming mode. Depending on
the code value, Quick Programming may be accessible before the
prompt
appears (see chart).
MODE WHEN “PAR”
KEY IS PRESSED