beautypg.com

Posey Double Security Mitts User Manual

Application instructions, Rx only double security mitts

background image

Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com

Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014

MDSS GmbH

Schiffgraben 41

D-30175 Hannover, Germany

EC REP

ApplicAtion

instructions

Applicable Products:

REF

2814, 2819

DEscription oF proDuct: Padded mitts without finger separators. Connecting straps (for hospital bed use only).

rx onlY

DoublE sEcuritY Mitts

© 2009 Posey Company. All rights reserved.

I9223 060609

2814

2819

ApplicAtion instructions (Repeat steps 1-4 for each mitt):

posEY FingEr control

Mitts

REF

2814

Double Security Mitts,

strap length 48½” (123 cm)

REF

2819

Double Padded, Double

Security Mitts, strap length

48¾” (124 cm)

1. Insert the patient’s hand into the mitt, palm down.

2.

Wrap the wrist strap around the smallest part of the

patient’s wrist, over the top of the wrist, through the plastic

ring, and secure it onto itself.

3.

Bring the second hook strap over the top of the loop strap

to form a “double security” closure.

4.

Slide ONE finger (flat) between the device and the inside of

the patient’s wrist to ensure proper fit. The strap must be

snug, but not compromise circulation.

Note: Follow steps 5-6 for use of optional bed connecting

strap (hospital bed use only) to help prevent the patient from

removing the device or inflicting self-injury:

5.

Wrap the strap around the patient’s wrist or pass it through

the loops on the mitt.

6.

Use Posey Quick-Release Tie (see drawings on reverse) to

secure the end of the strap to a movable part of the bed

frame. Tie strap at a point midway between the patient’s

wrist and elbow, out of the patient’s reach.

BeD SAFetY
• ALWAYS use Hospital Bed Safety

Workgroup (HBSW) (http://www.

fda.gov/cdrh/beds/modguide.html)

compliant side rails in the UP

position and fill ALL gaps to reduce the risk of

entrapment.

• Use side rail covers and gap protectors to help prevent

the patient’s body from going under, around, through or

between the side rails. A failure to do so may result in

serious injury or death if a patient becomes suspended

or entrapped. Posey offers a full range of side rail pads

and/or gap

protectors to

cover gaps.

inDicAtions For usE:
• Patients assessed to be at risk of disrupting life-saving treatments (e.g., chronic tube pulling).
• Patients assessed to be at risk of line pulling, which may prevent monitoring of vital signs.
• Patients whose picking, pulling, scratching, or peeling exacerbates a skin condition, causes

self-injury, or compromises wound site integrity.

NeVeR use mitts on a patient:

If an IV or wound site could be compromised by the device; or

With a dislocation or fracture on the affected limb.

See the Posey Catalog for other options for such a patient.

contrAinDicAtions:

Do Not use on a patient who is or becomes highly aggressive, combative, agitated, or suicidal.

ADVErsE rEActions

• Severe emotional, psychological, or physical problems may occur: if the applied device is

uncomfortable; or if it severely limits movement. If symptoms of these problems ever appear

for any reason, get help from a qualified medical authority and find a less restrictive, product or

intervention.

ADDitionAl sAFEtY AnD lAunDEring

instructions on othEr siDE

MONITOR PER FACILITY POLICY. Check to ensure that:
• Connecting straps cannot slide in any direction or loosen

if the patient pulls on them, or if the bed is adjusted;

• Mitts and straps are properly secured. If applied too

tightly, circulation will be restricted; if applied too

loosely, the patient may be able to slip his or her limb

from the device;

• Mitts are intact, not torn or damaged, and hook and

loop closes securely. DO NOT allow patients to ingest

mitt material;

• The patient cannot use his or her teeth or otherwise

remove the device and inflict self-injury;

• Monitor closely when the patient is out of bed. Patients

who ambulate while wearing this device may be at risk

of injury from a fall.

ADDITIONAL OR DIFFERENT BODY OR LIMB RESTRAINTS

MAY BE NEEDED (See Posey Catalog):
• If the patient pulls violently against the bed straps;
• To reduce the risk of the patient getting access to the line/

wound/tube site;

• To prevent the patient from flailing or bucking up and

down and causing self-injury.