Posey Toilet Seat Sensor User Manual
Posey, Single patient use toilet sensor pad, Before you begin
Single Patient Use Toilet Sensor Pad
Designed for toilet use with Posey Fall Alarms ONLY!
REF
8332 Single Patient Use Toilet Sensor Pad (30-Day)
Before You Begin
The Posey Sensor Pad, in conjunction with a Posey Alarm, is an
important part of your fall management protocols. Ensure all
parts of this system are operational before leaving a patient
unattended. This system does not prevent falls or injury from
falls and is not a substitute for patient care, caregiver rounding
and a comprehensive fall management protocol in your facility.
• This device may not be suitable for all high fall-risk patients. See
Posey catalog for other options for such patients.
•
NEVER use a restraint on a patient during toileting with this product.
• To prevent damage,
NEVER roll, fold, or crease sensor pad.
•
NEVER connect Posey sensor pads to other manufacturers’ alarm units.
•
NEVER connect Posey Alarms to other manufacturers’ sensor pads.
NOTE:
Before using this sensor pad, a Posey Fall Alarm must be
securely mounted near toilet, out of the patient’s reach.
Application Instructions:
1. Read all sensor pad and alarm instructions prior to use.
2. Check sensor pad, cord, and plug for damage. Discard entire sensor
pad if there is any damage.
3. Remove backing from adhesive patch.
NOT for use on toilet seats with risers or safety side arms.
To reduce the risk of serious injury or death:
1. ALWAYS test sensor pad before leaving patient unattended.
• Apply pressure to the toilet seat and then release.
Alarm should activate when you remove pressure.
• If sensor pad fails any test, stop use at once and replace
with a new sensor pad.
• Sensor pads past warranty expiration date may fail, causing
false alarm or no alarm.
8332
Cord
Clips
Bumper/
Standoff
Toilet
Seat
Toilet
Rim
2. Staff should ALWAYS be nearby and ready to respond if alarm
activates.
3. NEVER jerk or pull on sensor pad cord to remove plug. Doing so
will damage the cord or plug and may cause sensor pad to fail.
ALWAYS use plastic tab to release plug.
4.
If you remove alarm unit after toileting, make sure sensor
pad cord is out of the footpath and does not pose a
tripping hazard.
5. NEVER roll, fold or crease sensor pad.
This will damage sensor pad and may
cause false alarm or no alarm.
Cleaning:
• Make sure sensor pad has no visible cuts or signs of damage.
• Dampen a clean cloth with disinfectant. Take extra care when
cleaning sensor pad plugs.
•
NEVER: use any cleaner that contains Phenol; immerse in liquid;
or sterilize with heat.
• Dry with a clean cloth.
Storage:
• This device is designed for use in normal indoor environments.
• This device may be stored in ambient warehouse temperatures at
normal humidity levels. Avoid excess moisture or high humidity
that may damage product materials.
Disposal:
Dispose of per facility policy. Be sure to follow all laws
that apply.
Warranty:
This product is warrantied for thirty (30) days from date of first use.
See Posey Catalog for Warranty details.
4. Center sensor pad under the toilet seat “bumper” or “standoff”, on
top of the toilet rim. Make sure sensor pad cord is to the outside
(see drawing).
5. Press down firmly to attach sensor pad to toilet rim.
6. Route sensor pad cord to Posey alarm and insert plug. Check that
sensor pad cord is not stressed and does not pose a tripping hazard.
7. Use cord clips with adhesive backing to secure cord off floor. Attach
one clip to side of toilet. Attach second clip to wall, near sensor
pad.
8. Insert plug into sensor input on side of alarm.
© 2013 Posey Company. All rights reserved.
M6220C REV C 072913
Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com
Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014
MADE IN CHINA
Posey
®
Single Patient Use
Toilet Sensor Pad
FALL MANAGEMENT