beautypg.com

Posey Palm Grips User Manual

Posey, Hand therapy products, Posey palm cone

background image

Posey Palm Cone

The Palm Cone is a firm, cotton terry-covered plastic cone which

fits the palm of the hand. Adjustable foam strap accommodates

any size hand. May be used for exercise, or to help flexion

contractures of the hand. One size fits all; one per box.

REF

5608 5"L (13 cm)

Posey Finger Contracture Cushions

The Finger Contracture Cushion separates the fingers and helps

prevent the hand from closing completely. The cushion is filled

with polyester micro-fiber and is held onto the patient's hand by a

soft, expandable, latex free, spandex strap. Available in two sizes.

REF

6560 5”L x 3”W (13 cm x 8 cm)

REF

6562 5”L x 4”W (13 cm x 10 cm)

Posey Palm Grips

A soft, terry-covered palm device which gives patients something

to grip.

Polyester micro-fiber filled product comes with a soft,

expandable, latex-free, spandex strap.

REF

6507 Small 5"L x 2½"W (13 cm x 6 cm)

REF

6508 Large 5"L x 3"W (13 cm x 8 cm)

Posey Palm Cone with Finger Separators

This firm, cone-shaped anticontracture device conforms to the

hand's natural shape, while keeping fingers separated. Adjustable

foam strap with hook and loop closure accommodates all hand

sizes and secures the cone in the hand. One size fits all; one per

box.

REF

5609 5"L (13 cm)

Washing Instructions

Remove cone (Cat. Nos. 5608 and 5609) before

laundering to increase durability.

LATEX

LATEX

LATEX

LATEX

Inspection

Inspect before each use: check for broken stitches; or torn, cut or frayed material; DO NOT use soiled or damaged products.

Disposal

Properly dispose of the product per facility’s policy for

BIOHAZARDOUS materials.

Storage and Handling

This device is designed for use in normal indoor environments.

This device may be stored in ambient warehouse temperatures

at normal humidity levels. Avoid excess moisture or high

humidity that may damage product materials.

Monitoring

Be sure to follow your facility’s policies and guidelines for frequency of patient monitoring. Posey recommends that this product be

removed at least every two (2) hours to check for skin integrity, proper circulation and rehabilitation exercises.

5608

6508

5609

6562

M1356 REV B 010412

© 2012 Posey Company. All rights reserved.

Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com

Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014

THERAPY & AMBULATION

Posey

®

Hand Therapy Products

MDSS GmbH

Schiffgraben 41

D-30175 Hannover, Germany

EC REP

© 2012 Posey Company. All rights reserved.

This manual is related to the following products: