Bed Cradles and Foot Supports

Wound prevention

Posey metal bed cradles help keep bed sheets and

blankets away from sensitive skin. The multi-piece

take apart design reduces storage space. Self-locking

clamps lock the cradles in position on the mattress.

Designed to fit mattresses 35” to 37” (89 cm to 94 cm) wide. Not

for use on air mattresses.

REF

6430 Bed Cradle, standard bed, rectangular,

36”L x 21½”H (91 cm x 55 cm)

REF

6435 Bed Cradle, standard bed, triangular,

36’”L x 24”H (91 cm x 61 cm)

REF

6436 Foot Support, poly/cotton cover for 6430,

36”L x 21½”H (91 cm x 55 cm)

REF

6437 Foot Support, poly/cotton cover for 6435,

36”L x 24”H (91 cm x 61 cm)

ApplicAtion instructions:

Be sure to follow your facility’s policies and protocols

regarding frequency of patient monitoring. Posey

recommends following Agency for Healthcare Research

and Quality guidelines for removing skin coverings

at least every two hours to check skin integrity and

circulation.
1. Raise the sliding “V” spring clamp and place the lower

metal base under the mattress in the desired position.

2. Lower the spring clamp against the mattress to secure

the bed cradle. Press the center of clamp down to

lock. To release, press down on the inner ends of the

clamp fingers (fig. 1).

3. Assemble upper rod support and insert into uprights.

4. Apply Posey Foot Support Cover (6436/6437) to the

applicable bed cradle if so desired.

NOTE: The Posey Foot Support (Cat. No. 6436/6437)

will not prevent lateral footdrop. Only specific Posey

Footdrop Splints (Cat. #’s 6412/6405) should be used to

help prevent severe footdrop.

Fig. 1

6430

6436 and 6430 Shown with optional Foot

Support Cover

6435

MonitorinG

Be sure to follow your facility’s policies and

guidelines for frequency of patient monitoring. Posey

recommends that this product be removed at least

every two (2) hours to check for skin integrity, proper

circulation and range of motion.

LATEX

DisposAl

Properly dispose of the product per facility’s

policy for BIOHAZARDOUS materials.

Covers:

• These products can be machine washed under

CDC guidelines for material soiled with blood or

bodily fluid.

• For non-contaminated material, use lower temperature wash and dry cycles

to extend product life.

• Fasten all buckles to reduce risk of damage during wash and dry cycles. DO

NOT put buckles through extractors.

• Inspect all buckles and metal parts after drying. Discard if damaged.

Metal Frames:

• Wipe Clean with mild detergent. OSHA approved intermediate

level disinfectants can be used per manufacturer instructions.

• After cleaning, products MUST be rinsed with water to remove any

residual chemicals.

• Make sure products are completely dry before use.

M5034 042309

inspEction

Inspect before each use: check for broken

stitches or parts; torn, cut or frayed material; or buckles

that do not hold securely. DO NOT use soiled or

damaged products.

storAGE AnD HAnDlinG

This device is designed for use in normal indoor

environments. This device may be stored in ambient

warehouse temperatures at normal humidity levels.

Avoid excess moisture or high humidity that may

damage product materials.

clEAninG instructions:

lAunDErinG instructions: