beautypg.com

Posey Gap Fillers User Manual

Posey, Gap fillers

background image

Posey Gap Fillers easily fit around the perimeter of the

mattress to help eliminate gaps between the mattress and

the bed headboard/footboard/side rails to prevent potential

entrapment. Zippers allow you to connect multiple Gap

Fillers and create a custom length. Three pairs create a

border around most mattresses. Made of soft, durable

foam. Vinyl cover wipes clean. Meets CA #117, Section E

Flame Retardancy Standards.

REF

5715 Gap Fillers, one pair: 35”L x 6”H x 2”D

(89 cm x 15 cm x 5 cm)

Monitoring

Posey Gap Fillers will not prevent a determined

patient from exiting the bed, going over or attempting to

go between or through side rail gaps. DO NOT articulate

bed if product is applied.

ALWAYS follow your facility’s

policies and procedures for patient assessment, monitoring

and rehabilitation.

Application Instructions:

1. Inspect product prior to use. DO NOT use soiled or

damaged products.

2. Position the Gap Filler with the label towards the

bottom and the zipper away from the mattress.

3. At the selected location, slide the Gap Filler between

the mattress and the side rails (Fig. 1) or the head

footboard (Fig. 2).

4. Top of Gap Fillers should not fall below the top surface

of the mattress.

5. Gap Fillers should have a snug fit and should not be able

to slide out of place.

6. If the gap you are trying to fill is wider than 2 inches
(5 cm), multiple Gap Fillers can be zipped together to fill

in the gap (Fig. 3).

7. Check for proper fit. Modified beds may not be

compatible with Posey Gap Fillers.

Cleaning Instructions:

Wipe Clean with soap and water or

disinfectant.

Fig. 1

Fig. 2

Fig. 3

Disposal

Properly dispose of the product per facility’s

policy for BIOHAZARDOUS materials.

Storage and Handling

This device is designed for use in normal indoor

environments. This device may be stored in ambient

warehouse temperatures at normal humidity levels.

Avoid excess moisture or high humidity that may

damage product materials.

FDA/HBSW Entrapment Zone Mitigation

The Posey Gap Fillers may be useful in addressing FDA/

HBSW identified entrapment zones 1, 2, 3, 4, and 7 on

many Hospital/LTC/Homecare bed systems. Posey

recommends using the HBSW specified bed system

measurement tool to determine actual compliance of any

installation. For more information, visit http://www.fda.

gov/MedicalDevices/DeviceRegulationandGuidance/

GuidanceDocuments/ucm072662.htm

Refer to the Posey Catalog for the Posey product/bed

cross-reference guide to check for compatibility with

certain bed models.

© 2012 Posey Company. All rights reserved.

M6024 REV C 080712

Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com

Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014

Posey

®

Gap Fillers