beautypg.com

Heat pump tripping breaker, Heat pump won’t shut off – Aquacal LTM0266 User Manual

Page 36

background image

Page 30

SYMPTOM

RULE OUT

RESOLUTION

Water not
retaining heat

STEP 8:
If heating a spa, turn off water jets to allow for quicker
heating times. For pools, turn off water effects, such as
slides, waterfalls, or fountains to allow water to retain
heat more efficiently. Use of a liquid pool blanket
product, such as “Heatsavr

TM

”, can also compensate for

excessive heat loss.

STEP 9:
Call heat pump installer or AquaCal AutoPilot Customer
Support for further assistance.

Heat Pump Tripping Breaker

Weak breaker

STEP 1:
If breakers do not trip immediately, the issue is most
likely a weak breaker. Have an electrician confirm
breakers are in good condition and properly sized for
heat pump.

Incorrect heat
pump power
sequence

STEP 2:
Multiple heat pumps installed at the same site require
special automatic sequencing controllers to avoid
excessive power drops at start-up. Call heat pump
installer or AquaCal AutoPilot Customer Support for
further assistance on this type of equipment. See
“Automatic Sequencing Controller” in “Available
Accessories

” on page 35 for more information.

Compressor not
starting

STEP 3:

If fault occurs when a compressor turns on, service

will be required to determine compressor issue.
PLEASE NOTE

– Compressor failure is extremely

rare. Compressor failure must be determined before
replacement is considered. Call heat pump installer
or AquaCal AutoPilot Customer Support for further
assistance on this type of repair.

Heat Pump Won’t Shut Off

External
controller

STEP 1:

If an external controller is being used, confirm heat

pump is set to accept the controller’s signal. See
section entitled “External Controls / Equipment” on
page 22

and “Configuring for External Controller” on

page 24 for more information.

Determine if external controller has its own

thermostat. If yes, heat pump mode must be set to
“OFF”.

If heat pump is set correctly to accept an external

controller’s signal to turn off, contact the installer of
the external controller device or the device’s
manufacturer for further assistance.

Incorrect mode
setting

STEP 2:
Confirm the heat pump mode is set to “OFF”. See
“Setting Operating Mode” on page 3 for more
information.

STEP 3:
Call heat pump installer or AquaCal AutoPilot Customer
Support for further assistance.