GReddy Multi D/A Gauge System User Manual
Page 7
7.Troubleshooting
・ Indicating lower value.
・ With ignition on, the pointer
is not at zero.
・ With ignition off, the pointer
doesn’t come back at zero.
・ No ending demo.
・“Warning action” outside
the preset value.
・ Pointing strange value.
・ With power on, the pointer
doesn’t function.
Symptom
・ Grounding wire is not on the minus terminal
on the battery.
・ Miswiring.
Solution
Cause
・ Picking up noise from ignition signal or other
signals.
・ Wiring is short circuit.
・ Wiring is disconnected or break.
・ Sensor harness’s coupler is connected
mistakenly.
・ Power source and ignition power source
are not connected each other.
・ Extend the black line from the power source
and connect to the minus terminal.
・ Please refer to “4 Installation” and rewire
them.
・ Avoid noise occurring areas and reinstall
sensor harness.
・ Check if any damage on wire and if it is
touching car body or not.
・ Check if the coupler is disconnected or
the wire is damaged.
・ Check if the coupler is installed properly.
・ Wire power source and ignition power
separately.
Please refer to the following troubleshooting advices.
8. Service after the sales
Please don't hesitate to inform us if there is anything unclear.
If you find different manufacturing numbers between meter and power unit,
please bring it to the place you purchased or let us know directly.
Multi D/A Gauge is warranted for one year from the date of purchase against
manufacturer defects. Coverage is valid only with proof of purchase from an
Authorized Dealer. Alteration of this product will void warranty.
Additional services are available for a nominal charge.
-7-
TRUST CO., CO.LTD
3155 - 5 Odai Shibayama-machi Sanbu-gun Chiba, Japan 289-1605
TEL: +(81) - 479-77-0953
Email: [email protected]
Copyright
c 2009 TRUST-POWER.COM All right Reserved.
FAX: +(81) - 479-77-0947
August 2012 Printed