beautypg.com

GReddy Multi D/A Gauge System User Manual

Page 7

background image

7.Troubleshooting

Indicating lower value.

With ignition on, the pointer

is not at zero.

With ignition off, the pointer

doesn’t come back at zero.

No ending demo.

“Warning action” outside

the preset value.

Pointing strange value.

With power on, the pointer

doesn’t function.

Symptom

Grounding wire is not on the minus terminal

on the battery.

Miswiring.

Solution

Cause

Picking up noise from ignition signal or other

signals.

Wiring is short circuit.

Wiring is disconnected or break.

Sensor harness’s coupler is connected

mistakenly.

Power source and ignition power source

are not connected each other.

Extend the black line from the power source

and connect to the minus terminal.

Please refer to “4 Installation” and rewire

them.

Avoid noise occurring areas and reinstall

sensor harness.

Check if any damage on wire and if it is

touching car body or not.

Check if the coupler is disconnected or

the wire is damaged.

Check if the coupler is installed properly.

Wire power source and ignition power

separately.

Please refer to the following troubleshooting advices.

8. Service after the sales

Please don't hesitate to inform us if there is anything unclear.

If you find different manufacturing numbers between meter and power unit,
please bring it to the place you purchased or let us know directly.

Multi D/A Gauge is warranted for one year from the date of purchase against
manufacturer defects. Coverage is valid only with proof of purchase from an
Authorized Dealer. Alteration of this product will void warranty.

Additional services are available for a nominal charge.

-7-

TRUST CO., CO.LTD

3155 - 5 Odai Shibayama-machi Sanbu-gun Chiba, Japan 289-1605

TEL: +(81) - 479-77-0953

Email: [email protected]

Copyright

c 2009 TRUST-POWER.COM All right Reserved.

FAX: +(81) - 479-77-0947

August 2012 Printed