Actron KAL8600 User Manual
Page 5

5
2. Enter the battery CCA rating.
Use the UP/DOWN arrow keys to change the
CCA number of the battery to be tested. Press
and hold arrow key down for rapid scrolling.
Once the correct number is displayed, press
the \ key to continue.
NOTE: Do not be confused by CA rating. Use the CCA rating. To convert CA
or MCA (Marine) to CCA, multiply CA or MCA by 0.8.
3. Select Test based on battery temperature.
Use the UP/DOWN arrow keys to move the
pointer to the desired selection. Press \ key
to make selection. Use Above 32 °F selection
when battery temperature is above 32 ° F. Use
Below 32 ° F when battery temperature is be-
low 32 °F or lower.
4. Testing process.
Once the temperature range has been selected, the remaining battery tests will start
automatically.
After a short period, the analyzer displays the battery condition. After displaying the
battery condition test results, the analyzer determines the battery state-of-charge.
Below are the possible results and their meaning:
GOOD BATTERY
Indicates that the battery is good and ready to be returned to service.
GOOD-RECHARGE
Indicates that the battery is good but needs to be charged before returning it to
service.
REPLACE BATTERY
Indicates the battery is bad and needs to be replaced. Before replacing the battery
check the following:
Battery clamps had good connection on both sides during test. If not, correct
connections and retest.
If the battery was hooked up to the vehicle during testing, perform the following
steps:
- Disconnect the positive and negative cables from the battery to isolate it from
the vehicle
- Clean the battery posts or terminals.
- Connect analyzer and retest.
- If you still get the Replace Battery message, then the battery is bad and
needs to be replaced.
Enter Rated CCA 550
Use Arrow Keys
to Change Value
Press
*
Done
` Batt Above 32
o
F
Batt Below 32
o
F