beautypg.com

Actron 2513 User Manual

Model 2513 vacuum / pressure gauge kit

background image

VACUUM TESTING PROCEDURES

Running Engine Tests
1.

Connect the vacuum gauge to the manifold vacuum
source.

2.

Run the engine at normal operating temperature and
idle speed. A steady reading between 15 and 22
inches indicates a mechanically sound engine.

PCV Valve Test For Crankcase Ventilation
1.

Operate the engine at normal temperature and idle
speed.

2. Remove the hose connected between the air cleaner

and valve cover or oil filler/breather cap. Plug the oil
dipstick tube to prevent an air leak.

3. Hold the vacuum gauge with the rubber universal

adapter firmly over the valve cover hole or filler/
breather cap opening. A good PCV system will draw
a vacuum of 3 to 5 inches within 10 seconds.

Repair Parts List

Part Number

Description

Part Number

Description

0031-0424

Vacuum/Pressure Gauge

0180-1497

Conical Adapter

0400-3008

Gauge Boot

0400-3115

Fuel Line/Universal Adapter

0400-0384

Vacuum Hose, 24”

0400-3116

Carry Case

0400-3113

‘T’ Fitting

0001-3468

Instruction Label

0400-3114

In-line Connector

0001-000-3468

Model 2513 Vacuum / Pressure Gauge Kit

FUEL PRESSURE TESTING PROCEDURE

WARNING:

FOR USE ON FUEL SYSTEMS WITH A
CARBURETOR, OR LOW-PRESSURE
TBI SYSTEMS NOT EXCEEDING
15 PSI.

CAUTION:

USE EXTREME CARE IN
DISCONNECTING FUEL LINES.
LEAKING GASOLINE IS A SERIOUS
HAZARD.

1. Check all fittings, connections, and rubber fuel lines
for leaks. If leaks are present, repair leaks before
testing.
2. Disconnect the fuel line between the fuel pump and
the carburetor or the TBI system. Attach the gauge
hose to the fuel line using adapters as needed.
3. Operate the engine at idle speed and note reading.
On a good fuel pump, the pressure will range from
4 to 6 psi, with lower readings on smaller engines.

This manual is related to the following products: