Table 6. fxs/dpo mode options, Table 6, Fxs/dpo mode options – ADTRAN FXS/DPO/PLAR 1109403L2 User Manual
Page 8
![background image](/manuals/40277/8/background.png)
8
Issue 2, December 2004
61180403L1-5B
Table 6. FXS/DPO Mode Options
Mode
Description
Loop Start
This option selects ANSI T1.403 FXS Loop Start mode of operation.
Ground Start
This option selects ANSI T1.403 FXS Ground Start mode of operation.
TR08 Single Party
This option selects GR-08-Core Loop Start mode of operation.
TR08 Universal VG
This option selects GR-08-Core Ground Start mode of operation.
TR08 Auto
This option selects automatic detection of TR08 Single Party or TR08 Universal VG, based
on incoming signalling.
PLAR D4
This option selects Private Line Automatic Ringdown where onhook = 00. Signaling must
match the PLAR unit at the distant end.
PLAR D3
This option selects Private Line Automatic Ringdown where onhook = 11. Signaling must
match the PLAR unit at the distant end.
Tandem
This option selects A/B signaling on the Network side for use with a Class 4 Tandem switch.
DPO
This option selects Dial Pulse Originate for Direct-Outward Dial applications.
FX Ringdown
This is the PLAR mode of operation that allows for a FXS Loop Start unit on the distant end.
TO w/SC
This option disables signaling for Transmission Only with Sealing Current enabled. Used in 2
w/TO applications where the Network Customer Termination Equipment (NCTE) or
Customer premise equipment provide for termination of the sealing current (sealing current
sink).