Installation preparation, Determine installation height – GE ZV925SLSS User Manual
Page 6

DETERMINE INSTALLATION HEIGHT
• Decorative duct covers are provided to conceal the
ductwork running to the ceiling.
• This hood can be installed for recirculating
operation. No kits required.
The hood installation height, from the cooking
surface to the bottom of the hood, depends upon
ceiling height.
For optimum performance, the hood must be 24"
min. and 30" max. above the cooking surface.
Use the chart on this page to accurately determine
installation height and support frame adjustment,
and to select the correct size top trim piece (A, B, C
or D).
ZX92510 Accessory Duct cover includes a 36-3/4"
long duct cover and 3 sets of duct cover top trim
pieces labeled E, F, G.
Possible
Hood Mounting
Ceiling
Installation
Frame
Trim Piece
Height Height (inches) Height (inches) Needed
7'-11"
26
30
1/2
A
8'
27 30
1/2
A
8'-1"
24
34
1/2
B
8'-1"
28
30
1/2
A
8'-2"
25
34
1/2
B
8'-2"
29
30
1/2
A
8'-3"
26
34
1/2
B
8'-3"
30
30
1/2
A
8'-4"
27
34
1/2
B
8'-5"
24
38
1/2
C
8'-5"
28
34
1/2
B
8'-6"
25
38
1/2
C
8'-6"
29
34
1/2
B
8'-7"
26
38
1/2
C
8'-7"
30
34
1/2
B
8'-8"
27
38
1/2
C
8'-9"
24
42
1/2
D
8'-9"
28
38
1/2
C
8'-10"
25
42
1/2
D
8'-10"
29
38
1/2
C
8'-11"
26
42
1/2
D
8'-11"
30
38
1/2
C
9'
27
42
1/2
D
ZX92510 Accessory Duct Cover
9'-1"
24
46
1/2
E
9'-1"d 28
42
1/2 D
9'-2"
25
46
1/2
E
9'-2"
29
42
1/2
D
9'-3"
26
46
1/2
E
9'-3"
30
42
1/2
D
9'-4"
27
46
1/2
E
9'-5"
24
50
1/2
F
9'-5"
28
46
1/2
E
9'-6"
25
50
1/2
F
9'-6"
29
46
1/2
E
9'-7"
26
50
1/2
F
9'-7"
30
46
1/2
E
9'-8"
27
50
1/2
F
9'-9"
24
54
1/2
G
9'-9"
28
50
1/2
F
9'-10"
25
54
1/2
G
9'-10"
29
50
1/2
F
9'-11"
26
54
1/2
G
9'-11"
30
50
1/2
F
10'
27
54
1/2
G
10'-1"
28
54
1/2
G
6
Installation Preparation
D
C
B
A