beautypg.com

Setting the scsi ids for the disk modules, Figure 7, Scsi switch location – HP 2120 Disk System User Manual

Page 13: Table 4, Scsi switch setting definitions

background image

13

HP StorageWorks Disk System 2120

Eng

lish

Setting the SCSI IDs for the Disk Modules

1

Determine which SCSI addresses are not being used on the host system.

Refer to your system administration manual for information on determining
which SCSI addresses are available on the host system.

2

Locate the SCSI switch on the back of the disk system.

FIGURE 7

SCSI Switch Location

3

Set the SCSI IDs.

Verify that the SCSI IDs you have chosen are available. If you are daisy-chaining
these disk systems together, each SCSI ID switch must be set for a unique
available set of SCSI IDs.

TABLE 4

SCSI Switch Setting Definitions

SCSI

Switch

Setting

Disk Slot

1

2

3

4

A

0

2

4

6

B

8

10

12

14

C

9

11

13

15

0

8

9

2

10

11

4

12

13

6

14

15

A

B

C

SCSI

Address

Switch

Setting

Disk Module SCSI Addresses (Viewed from front of storage enclosure)

C
B
A