beautypg.com

Hp 350 w 4u factory integrated power supply, Hot-plug power supply calculations – HP ProLiant ML310e Gen8 Server User Manual

Page 91

background image

Specifications 91

HP 350 W 4U Factory Integrated Power Supply

Specification

Value

Input requirements

Rated input voltage

100 V AC to 240 V AC

Rated input frequency

47 Hz to 63 Hz

Rated input current

6 A

Rated input power

440 W at 100 V AC input

440 W at 200 V AC input

Efficiency

No less than 82% at 100% load
No less than 85% at 50% load

No less than 82% at 20% load

Power supply output

Rated steady-state power

350 W at 100 V AC input
350 W at 200 V AC input

Maximum peak power

400 W at 100 V AC input

400 W at 200 V AC input

Rated output power

350 W

HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)

Specification

Value

Input requirements

Rated input voltage

100 V AC to 240 V AC

Rated input frequency

50 Hz to 60 Hz

Rated input current

6 A to 3 A

Rated input power

526 W at 115 V AC input

523 W at 230 V AC input

Power supply output

Efficiency

Not less than 87.5% at 100% load
Not less than 89.5% at 50% load

Not less than 87.5% at 20% load

Rated steady-state power

460 W at 100 V to 120 V AC

input
460 W at 200 V to 240 V AC

input

Maximum peak power

460 W at 100 V to 120 V AC

input
460 W at 200 V to 240 V AC

input

Hot-plug power supply calculations

For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, refer to the HP Enterprise Configurator website (

http://h30099.www3.hp.com/configurator/

).