Power specifications, Environmental specifications – HP StorageWorks 20 Modular Smart Array User Manual
Page 43
Specifications
C-2
HP StorageWorks Modular Smart Array 20 User Guide
Power Specifications
Table C-3: AC Input Requirements
Nominal
Value
Range
Frequency (±5%)
50 or 60 Hz
47 to 63 Hz
Voltage
110 or 240 V
90 to 254 V RMS
(autoranging)
Steady state
maximum current
At 240 V: 1.8 A (one power supply) or 1.9 A (two
power supplies)
At 120 V: 3.7 A (one power supply) or 3.9 A (two
power supplies)
—
Standby current
0.21 A at 240 V, 60 Hz
0.15 A at 120 V, 60 Hz
—
Environmental Specifications
Table C-4: Environmental Specifications
Operating
Shipping or Storage
Ambient
temperature
10° to 35°C (50° to 95°F), with an average change
of less than 1°C per hour and a step change of
less than 3°C per hour
–40° to 66°C
–40° to 150°F
Relative humidity
(noncondensing)
40% to 60%, with a step change of less than 10%
10% to 80%
Air quality
Fewer than 500,000 particles 0.5 micron or larger
per cubic foot (approximately 17,700 per liter)
—
Heat dissipation
1175 BTU/hr (345 W)
—
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)