Chapter 3: installing the enclosure in a rack, Preparing the rack, Removing the enclosure components – HP StorageWorks 20 Modular Smart Array User Manual
Page 19: Removing the enclosure components -1, Chapter 3, Installing the enclosure in a rack, Preparing the rack -1

HP StorageWorks Modular Smart Array 20 User Guide
3-1
components from an enclosure that is not being used. To remove individual components from
a working enclosure, refer to the complete instructions in Chapter 5.
3
Installing the Enclosure in a Rack
Installing the enclosure in a rack involves four steps:
•
Preparing the rack
•
Removing the enclosure components to make the enclosure more manageable
•
Mounting the enclosure in the rack
•
Completing the installation process (reinstalling the components and connecting
the power)
Preparing the Rack
The racks that HP supports for use with the MSA20 enclosure are the HP System E
racks and the HP 10000 Series racks. Other racks might also be suitable, but have not
been tested with the MSA20.
For information about setting up a rack, including appropriate warnings and cautions,
refer to the relevant rack user guide.
Before mounting the enclosure in a rack, confirm that the rack location meets the
environmental requirements for the enclosure as described in Appendix C.
Removing the Enclosure Components
IMPORTANT: The following abbreviated instructions are appropriate for removing the