Advanced ecc memory, Dimm installation guidelines, Dimm population order – HP ProLiant BL495c G5 Server-Blade User Manual
Page 21: Installing dimms
![background image](/manuals/398383/21/background.png)
Advanced ECC memory
Advanced ECC memory is the default memory protection mode for this server blade. In Advanced ECC,
the server blade is protected against correctable memory errors. The server blade provides notification if
the level of correctable errors exceeds a pre-defined threshold rate. The server blade does not fail
because of correctable memory errors. Advanced ECC provides additional protection over Standard ECC
because it is possible to correct certain memory errors that would otherwise be uncorrectable and result in
a server blade failure.
Whereas standard ECC can correct single-bit memory errors, Advanced ECC can correct single-bit
memory errors and multi-bit memory errors if all failed bits are on the same DRAM device on the DIMM.
DIMM installation guidelines
CAUTION:
Always wear an antistatic wrist strap when working inside the server.
Observe the following guidelines when installing additional memory:
•
Install only ECC PC2-5300 Registered DDR2 SDRAM DIMMs
•
Always install DIMMs in sequence (1A, 2A, 3B, 4B).
•
DIMMs must always be installed in pairs.
•
HP recommends installing DIMMs with the greatest capacity in the banks farthest from each
populated processor first.
•
mber.
DIMMs installed in the same memory bank must have the same part nu
•
DIMMs installed in different banks can be of different sizes.
nel mode and Advanced ECC. To select a mode, use RBSU ("
HP ROM-Based Setup Utility
"
on page
40
).
A
D
2F
14G
H, 16H
For DIMM slot locations, see "System board components (on page
Each server supports multiple memory modes, based on DIMM population. The system will default to
combined chan
DIMM population order
Bank A
1A, 2
Bank B
3B, 4B
Bank C
5C, 6C
Bank D
7D, 8
Bank E
9E, 10E
Bank F
11F, 1
Bank G
13G,
Bank H
15
Single
processor
1st
2nd
3rd
4th
— — — —
Two
processors
1st 3rd 5th 7th 2nd 4th 6th
8th
Installing DIMMs
surfaces, allow the drives and the
internal system components to cool before touching them.
WARNING:
To reduce the risk of personal injury from hot
To install the component:
1.
Power down the server blade (on page
Hardware options installation 21