beautypg.com

A using raid manager for auto lun, Auto lun and raid manager commands, Migrating volumes with raid manager – HP XP Racks User Manual

Page 32: Interoperability of auto lun and raid manager

background image

A Using RAID Manager for Auto LUN

Use RAID Manager from an open-system host to perform migration operations on open-system and
mainframe volumes.

Auto LUN and RAID Manager commands

The following figure illustrates the different states of Auto LUN pairs when using RAID Manager
commands.

Figure 5 Auto LUN Pairs and RAID Manager Commands

The status of a pair can be checked by using the pairdisplay RAID Manager command.

Migrating volumes with RAID Manager

In this example, group1 represents the group name in the RAID Manager configuration definition
file, and pair1 represents the name of the volume whose pair is the target volume of the operation.

Procedure 5 To perform a migration using RAID Manager commands:

1.

Start RAID Manager.

2.

Type the following command for a SMPL pair to start volume migration:

paircreate -g group1 -d pair1 -m cc -v1

When volume migration starts, the status of the pair changes to COPY.

3.

Type the following command to check the status of the pair:

pairdisplay –g group1 –d pair1 -fcex

When volume migration completes, the status of the pair changes to PSUS. If volume migration
fails, the status of the pair changes to PSUE.

4.

Type the following command to change the pair status back to SMPL:

pairsplit –S –g group1 –d pair1

If the migration fails (the status of the pair becomes PSUE), repeat step 2 and 3. If you are
unable to change the pair status back to SMPL, contact the service engineer.

Interoperability of Auto LUN and RAID Manager

When you perform an Auto LUN plan by using RAID Manager commands, note the following:

A volume reserved through Auto LUN cannot be used as a target volume

A migration plan being executed by Auto LUN cannot be canceled using RAID Manager

A migration plan created by Auto LUN cannot be displayed using RAID Manager

Click File > Refresh All on the menu bar of the Remote Web Console main window to check
RAID Manager settings in Remote Web Console

While the microcode is being downgraded or upgraded, users must not perform any operations
that the resulting microcode would not support

32

Using RAID Manager for Auto LUN

This manual is related to the following products: