Log-target – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 60

Command line 60
Item
Description
Syntax
set local-users [Enabled=
[PrimaryRemoteAuthenticationMethod= tacacs>] Properties Enabled (optional) Enables or disables local user authentication for the VC domain. Valid values are "true" Disabling or enabling local user authentication requires you to be logged in as an modified if you are logged in as a local user. PrimaryRemote Authentication Method (optional) The primary authentication mechanism that triggers the re-enablement of local user authentication (if it was disabled), in case the remote authentication servers are found Example -> set local-users Enabled=false PrimaryRemoteAuthenticationMethod=tacacs Disables local user authentication Item Description show local-users Display local user authentication settings for the VC domain. show local-users Example ->show local-users Displays local user authentication settings log-target Manage remote log destination settings. Item Description add log-target Add a new remote log destination. Syntax add log-target [Severity= [Transport= [Security= [State= Properties Destination (required) The IPv4 address or the DNS name of the remote log destination Severity (optional) The severity of the log messages that should be sent to the specified destination. Transport (optional) The transport protocol to be used for sending the log messages to the destination. Valid values include "TCP" and "UDP". The default value is "UDP". Port (optional) The port to be used on the destination to send the log messages. Valid values
and "false". The default value is "true".
LDAP, RADIUS or TACACS user with domain privileges. This property cannot be
Disabling local user authentication without specifying the
PrimaryRemoteAuthenticationMethod is not allowed.
to be unavailable during login by a remote VCM user. Valid values include "none",
"ldap", "radius", and "tacacs". The default value is "none".
Syntax
Supported actions: add, help, remove, set, show, test
Valid values include "Critical", "Error", "Warning", and "Info". The default value
is "Info".
include 1 to 65536. The default value is 514.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10.10D Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem